• myGriffith
    • Staff portal
    • Contact Us⌄
      • Future student enquiries 1800 677 728
      • Current student enquiries 1800 154 055
      • International enquiries +61 7 3735 6425
      • General enquiries 07 3735 7111
      • Online enquiries
      • Staff phonebook
    View Item 
    •   Home
    • Griffith Research Online
    • Conference outputs
    • View Item
    • Home
    • Griffith Research Online
    • Conference outputs
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Browse

  • All of Griffith Research Online
    • Communities & Collections
    • Authors
    • By Issue Date
    • Titles
  • This Collection
    • Authors
    • By Issue Date
    • Titles
  • Statistics

  • Most Popular Items
  • Statistics by Country
  • Most Popular Authors
  • Support

  • Contact us
  • FAQs
  • Admin login

  • Login
  • Effect of pressboard ageing on power transformer mechanical vibration characteristics

    Author(s)
    Naranpanawe, WMLB
    Bandara, KMKS
    Saha, TK
    Ekanayake, C
    Annamalai, Pratheep Kumar
    Griffith University Author(s)
    Ekanayake, Chandima MB.
    Year published
    2015
    Metadata
    Show full item record
    Abstract
    Power transformer winding clamping pressure is a critical parameter, which is directly related to transformer short circuit ride through capability. Mechanical impacts generated on the winding structure during short circuit faults, switching surges and other high current faults have a significant impact on the winding clamping structure and could lead to reduce the clamping pressure. The change in clamping pressure influences the vibration behaviour of winding structure. Hence, variations in clamping pressure can be assessed by monitoring the transformer vibrations. However, it has been observed that, not only progressive ...
    View more >
    Power transformer winding clamping pressure is a critical parameter, which is directly related to transformer short circuit ride through capability. Mechanical impacts generated on the winding structure during short circuit faults, switching surges and other high current faults have a significant impact on the winding clamping structure and could lead to reduce the clamping pressure. The change in clamping pressure influences the vibration behaviour of winding structure. Hence, variations in clamping pressure can be assessed by monitoring the transformer vibrations. However, it has been observed that, not only progressive loss of clamping pressure but also solid insulation ageing has a significant influence on the winding vibration characteristics. Therefore, for a proper analysis of transformer vibration a clear understanding of the effect of solid insulation ageing on vibration behaviour of transformer winding structure is essential. This study aims to investigate the sensitivity of the transformer winding vibration characteristics to ageing of solid insulation material. Variations in modal parameters of winding structure with solid insulation ageing is studied using Finite Element Modelling (FEM). Results are used to discuss the sensitivity of winding vibrations to solid insulation ageing.
    View less >
    Conference Title
    2015 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC)
    DOI
    https://doi.org/10.1109/APPEEC.2015.7380951
    Subject
    Power and Energy Systems Engineering (excl. Renewable Power)
    Publication URI
    http://hdl.handle.net/10072/123498