• myGriffith
    • Staff portal
    • Contact Us⌄
      • Future student enquiries 1800 677 728
      • Current student enquiries 1800 154 055
      • International enquiries +61 7 3735 6425
      • General enquiries 07 3735 7111
      • Online enquiries
      • Staff phonebook
    View Item 
    •   Home
    • Griffith Research Online
    • Conference outputs
    • View Item
    • Home
    • Griffith Research Online
    • Conference outputs
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Browse

  • All of Griffith Research Online
    • Communities & Collections
    • Authors
    • By Issue Date
    • Titles
  • This Collection
    • Authors
    • By Issue Date
    • Titles
  • Statistics

  • Most Popular Items
  • Statistics by Country
  • Most Popular Authors
  • Support

  • Contact us
  • FAQs
  • Admin login

  • Login
  • The Effect of Conductivity Values on Activation Times and Defibrillation Thresholds

    Author(s)
    Johnston, Barbara M
    Barnes, Josef P
    Johnston, Peter R
    Griffith University Author(s)
    Johnston, Barbara M.
    Johnston, Peter R.
    Barnes, Josef P.
    Year published
    2016
    Metadata
    Show full item record
    Abstract
    Uncertainty in the input parameters used in simulation studies needs to be taken into account when evaluating the results produced. This work considers the effect of using various sets of bidomain conductivity values in two simulations: firstly, activation times, which indicate the propagation of the depolarisation wavefront through the cardiac tissue, and, secondly, the determination of defibrillation thresholds in a ‘heart in a bath’ model, where a shock is delivered from two opposing patch electrodes. Both simulations use the same two types of sets of bidomain conductivity values: four-conductivity datasets (where normal and ...
    View more >
    Uncertainty in the input parameters used in simulation studies needs to be taken into account when evaluating the results produced. This work considers the effect of using various sets of bidomain conductivity values in two simulations: firstly, activation times, which indicate the propagation of the depolarisation wavefront through the cardiac tissue, and, secondly, the determination of defibrillation thresholds in a ‘heart in a bath’ model, where a shock is delivered from two opposing patch electrodes. Both simulations use the same two types of sets of bidomain conductivity values: four-conductivity datasets (where normal and transverse conductivities are assumed equal) and sixconductivity datasets, including newly proposed sets that are based on experimental measurements. The activation time maps show significant differences depending on the conductivity set used, as do the defibrillation thresholds. The defibrillation thresholds vary by more than 20%, whereas the activation times for epicardial breakthrough and total depolarisation both vary by approximately 50%. It is found that the most extreme values in each case are produced by two of the four-conductivity datasets. Since these differences are large enough to lead to different conclusions in such studies, it is suggested that the four-conductivity datasets may not be an appropriate choice for use in simulation studies in the heart.
    View less >
    Conference Title
    2016 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), VOL 43
    Volume
    43
    DOI
    https://doi.org/10.23919/CIC.2016.7868704
    Subject
    Biological mathematics
    Publication URI