Analysis of Eddy Current Distribution in High Frequency Coaxial Transformer with Faraday Shield
View/ Open
Author(s)
Lu, J
Dawson, F
Griffith University Author(s)
Year published
2006
Metadata
Show full item recordAbstract
This paper presents the analysis and measurement results for a high frequency (HF) coaxial transformer with Faraday shield. The simulation results demonstrate that the magnetic flux and eddy current distribution are not impacted by the inclusion of a Faraday shield. The Faraday shield's maximum eddy current density is less than 17% of the maximum density found in the secondary windings.This paper presents the analysis and measurement results for a high frequency (HF) coaxial transformer with Faraday shield. The simulation results demonstrate that the magnetic flux and eddy current distribution are not impacted by the inclusion of a Faraday shield. The Faraday shield's maximum eddy current density is less than 17% of the maximum density found in the secondary windings.
View less >
View less >
Conference Title
INTERMAG 2006 - IEEE International Magnetics Conference
Copyright Statement
© 2006 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE.