Show simple item record

dc.contributor.authorLiang, Ryan
dc.contributor.authorGeorge, Roy
dc.contributor.authorWalsh, Laurence J
dc.date.accessioned2018-10-26T02:08:02Z
dc.date.available2018-10-26T02:08:02Z
dc.date.issued2016
dc.identifier.issn0268-8921
dc.identifier.doi10.1007/s10103-016-2055-z
dc.identifier.urihttp://hdl.handle.net/10072/142986
dc.description.abstractThe aim of this study was to evaluate pulpal responses in healthy human teeth to photo-biomodulation therapy (PBMT) with 904-nm GaAs diode laser. The study followed a double-blind split mouth design, with a randomly selected maxillary first premolar acting as a sham-irradiated control tooth, and the contralateral tooth receiving active laser treatment. Two coded but otherwise identical laser probes (Irradia™, SpectraMedics Ltd., NC, USA) were used to deliver the sham (placebo) and laser radiation, with both the operator and patient unaware of each probe’s identity. The selection of teeth for sham or laser irradiation was randomised for each treatment. Pulpal responses were assessed using electric pulp testing (EPT), 2 min prior to exposure, and immediately after laser irradiation (60 s, 30 mW average power, 25 Hz pulse frequency, 3.6 J/cm2). Treatment effects were analysed using the Wilcoxon-signed rank test. A total of 30 participants provided written informed consent. Majority of the participants (66.7 %) demonstrated an analgesic effect following PBMT (elevated EPT scores); however, nine participants (30 %) reported the lower EPT scores than the control. Both the treatment effects (stimulation and analgesia) were significant compared to the placebo. In most individuals, PBMT of healthy teeth with a 904-nm GaAs diode laser can induce analgesia, as witnessed by elevated EPT scores. A converse effect can occur in a minority of subjects.
dc.description.peerreviewedYes
dc.languageEnglish
dc.language.isoeng
dc.publisherSpringer
dc.relation.ispartofpagefrom1
dc.relation.ispartofpageto7
dc.relation.ispartofjournalLasers in Medical Science
dc.subject.fieldofresearchBiomedical engineering
dc.subject.fieldofresearchBiomedical engineering not elsewhere classified
dc.subject.fieldofresearchcode4003
dc.subject.fieldofresearchcode400399
dc.titlePulpal response following photo-biomodulation with a 904-nm diode laser: a double-blind clinical study
dc.typeJournal article
dc.type.descriptionC1 - Articles
dc.type.codeC - Journal Articles
gro.facultyGriffith Health, School of Dentistry and Oral Health
gro.description.notepublicThis publication has been entered into Griffith Research Online as an Advanced Online Version.
gro.hasfulltextNo Full Text
gro.griffith.authorGeorge, Roy


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

  • Journal articles
    Contains articles published by Griffith authors in scholarly journals.

Show simple item record