Show simple item record

dc.contributor.authorRickard, CM
dc.contributor.authorCouchman, BA
dc.contributor.authorSchmidt, SJ
dc.contributor.authorDank, A
dc.contributor.authorPurdie, DM
dc.date.accessioned2019-04-07T23:00:57Z
dc.date.available2019-04-07T23:00:57Z
dc.date.issued2003
dc.date.modified2007-10-23T07:48:24Z
dc.identifier.issn0090-3493
dc.identifier.doi10.1097/01.CCM.0000063448.98777.EF
dc.identifier.urihttp://hdl.handle.net/10072/15307
dc.description.abstractObjective: To determine the blood discard volume, as a multiple of deadspace, that is required for accurate arterial blood gas and electrolyte testing from arterial catheters. Design: Prospective, controlled, crossover trial. Setting: Eighteen-bed intensive care unit of a metropolitan teaching hospital. Patients: A total of 84 critically ill patients with a 20-gauge, radial arterial cannulae, pressure monitoring transducer set, and stable oxygenation. Interventions: System deadspace (priming volume from sampling port to catheter tip) was established. Patients had six 0.5-mL arterial blood samples taken sequentially in random order using discard volumes of 1, 1.5, 2, 2.3, and 3.6 times the deadspace (experimental values) and 5.5 times the deadspace (control). Measurements and Main Results: Samples were analyzed for Pao2, Sao2, pH, Paco2, HCO3 −, Na+, and K+. We performed repeated-measures analysis of variance with post hoc linear contrasts and compared mean experimental and control values. The smallest discard volumes that provided measurements that were statistically equal to control were twice the deadspace (Pao2, p = .563; Sao2, p = .371) and 3.6 times the deadspace (pH, p = .107; Paco2, p = .519; HCO3 −, p = .10). All discard volumes tested provided results that were statistically different from control for Na+ (p < .003) and K+ (p < .001). Conclusions: Many results were statistically different from control, although the actual discrepancies were very small. At clinically relevant levels of measurement, there was minimal variation between values obtained after a discard volume of twice the deadspace and control values. The level of error was clinically acceptable and within or close to the precision limits of the blood gas analyzer. Slight fluctuation in patient variables during sampling could also have contributed to the error. A blood discard volume of twice the deadspace is recommended for all variables. This will provide clinically accurate results and avoid the deleterious effects of unnecessary blood loss.
dc.description.peerreviewedYes
dc.description.publicationstatusYes
dc.languageEnglish
dc.language.isoeng
dc.publisherLippincot Wilkins Williams
dc.publisher.placeUnited States
dc.relation.ispartofpagefrom1654
dc.relation.ispartofpageto1658
dc.relation.ispartofissue6
dc.relation.ispartofjournalCritical Care Medicine
dc.relation.ispartofvolume31
dc.subject.fieldofresearchClinical sciences
dc.subject.fieldofresearchNursing
dc.subject.fieldofresearchcode3202
dc.subject.fieldofresearchcode4205
dc.titleA discard volume of twice the deadspace ensures clinically accurate arterial blood gases and electrolytes and prevents unnecessary blood loss
dc.typeJournal article
dc.type.descriptionC1 - Articles
dc.type.codeC - Journal Articles
gro.date.issued2003
gro.hasfulltextNo Full Text
gro.griffith.authorRickard, Claire


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

  • Journal articles
    Contains articles published by Griffith authors in scholarly journals.

Show simple item record