Verbal numerical scales are as reliable and sensitive as visual analog scales for rating dyspnea in young and older subjects
Author(s)
Morris, NR
Sabapathy, S
Adams, L
Kingsley, RA
Schneider, DA
Stulbarg, MS
Year published
2007
Metadata
Show full item recordAbstract
This study compared the use of a simple verbal 0-10 numerical rating scale (verbal NRS) and a visual analog scale (VAS) for the rating of dyspnea during exercise in a group of young and older subjects. Twelve younger (32 ᠹ yr) and 12 older (71 ᠷ yr) subjects used either the verbal NRS or the VAS in a randomised fashion to rate dyspnea during 60 s of uphill treadmill walking (range 5.6-8.8 km h-1) performed at either a low (17% grade) or high workload (26% grade) and then during recovery. Rating scales were evaluated twice on separate days (day 1 and day 2) at each workload. While the verbal NRS scores proved to be reliable ...
View more >This study compared the use of a simple verbal 0-10 numerical rating scale (verbal NRS) and a visual analog scale (VAS) for the rating of dyspnea during exercise in a group of young and older subjects. Twelve younger (32 ᠹ yr) and 12 older (71 ᠷ yr) subjects used either the verbal NRS or the VAS in a randomised fashion to rate dyspnea during 60 s of uphill treadmill walking (range 5.6-8.8 km h-1) performed at either a low (17% grade) or high workload (26% grade) and then during recovery. Rating scales were evaluated twice on separate days (day 1 and day 2) at each workload. While the verbal NRS scores proved to be reliable throughout exercise and recovery, VAS scores were significantly (p < 0.05) lower on day 2 during the low workload test (younger group) and the high workload test (older group). Verbal NRS ratings were consistently greater than VAS ratings at both workloads (p < 0.001) for both young and older groups. The intra-class correlation coefficients for rating peak dyspnea using either the VAS or verbal NRS were consistently lower for the older subjects (range: r = 0.54-0.67) than the younger subjects (range: r = 0.70-0.86). Overall, subjects preferred the verbal NRS to the VAS. These results suggest that the verbal NRS compares favourably with the VAS for rating dyspnea during exercise without mask or mouthpiece. However, when rating peak dyspnea both scales appear less reliable when used by the older compared to young subjects.
View less >
View more >This study compared the use of a simple verbal 0-10 numerical rating scale (verbal NRS) and a visual analog scale (VAS) for the rating of dyspnea during exercise in a group of young and older subjects. Twelve younger (32 ᠹ yr) and 12 older (71 ᠷ yr) subjects used either the verbal NRS or the VAS in a randomised fashion to rate dyspnea during 60 s of uphill treadmill walking (range 5.6-8.8 km h-1) performed at either a low (17% grade) or high workload (26% grade) and then during recovery. Rating scales were evaluated twice on separate days (day 1 and day 2) at each workload. While the verbal NRS scores proved to be reliable throughout exercise and recovery, VAS scores were significantly (p < 0.05) lower on day 2 during the low workload test (younger group) and the high workload test (older group). Verbal NRS ratings were consistently greater than VAS ratings at both workloads (p < 0.001) for both young and older groups. The intra-class correlation coefficients for rating peak dyspnea using either the VAS or verbal NRS were consistently lower for the older subjects (range: r = 0.54-0.67) than the younger subjects (range: r = 0.70-0.86). Overall, subjects preferred the verbal NRS to the VAS. These results suggest that the verbal NRS compares favourably with the VAS for rating dyspnea during exercise without mask or mouthpiece. However, when rating peak dyspnea both scales appear less reliable when used by the older compared to young subjects.
View less >
Journal Title
Respiratory Physiology & Neurobiology
Volume
157
Issue
2-3
Publisher URI
Subject
Cardiovascular medicine and haematology
Neurosciences
Medical physiology