Show simple item record

dc.contributor.convenorW. Brown,en_AU
dc.contributor.authorWixted, Andrewen_US
dc.contributor.authorJames, Danielen_US
dc.contributor.authorBusch, Andrewen_US
dc.contributor.authorPortus, Marcen_US
dc.contributor.editorW. Brown, A. Green, L. Cook, A. Bauman, L. Otagoen_US
dc.date.accessioned2017-04-24T08:24:02Z
dc.date.available2017-04-24T08:24:02Z
dc.date.issued2009en_US
dc.date.modified2010-07-09T03:08:52Z
dc.identifier.urihttp://hdl.handle.net/10072/31725
dc.description.abstractIntroduction: In the laboratory environment biomechanical characteristics of cricket fast bowlers are assessed using a variety of analysis systems such as retro-reflective motion analysis systems (e.g. VICON). In general these systems allow for detailed and sophisticated analysis of human movement but are limited to the contrived laboratory environment. Previous studies into bowling actions have typically relied upon frame by frame high speed match video analysis or 3 dimensional motion analysis obtained in a laboratory setting. It is generally considered that laboratory analyses provide a more detailed and accurate analysis of bowling actions including "suspect action" but do not provide a "real world" analysis environment. Methodology and Results: Using previously developed wearable technology it is possible to measure arm action at a number of points on the bowling arm. The technology is based on inertial sensors and measures the arms changes in motion hundreds of times a second. These sensors respond to minute changes in inertia in linear and radial directions. These are known as accelerometers and rate gyroscopes, respectively. When combined with absolute positioning technologies such as magnetometers and even GPS (Global Positioning System), laboratory equivalent performance analysis can be obtained.. By comparing the movement of different limb segments it is possible to devolve a detailed picture of arm action.. Case study results from a sub elite bowler show clear differences between throwing and bowling action with elbow abduction and extension being clearly evident signatures in the data Conclusions: The sensors have been shown to be able to classify arm action with comparable accuracy to existing lab based methods. It is hoped that with more complete validation this technology can be used as a training tool to aid in the correction of bowling action to prevent injury, improve performance and correct suspect action.en_US
dc.description.publicationstatusYesen_AU
dc.languageEnglishen_US
dc.language.isoen_AU
dc.publisherSports Medicine Australiaen_US
dc.publisher.placeACTen_US
dc.relation.ispartofstudentpublicationNen_AU
dc.relation.ispartofconferencenamebe active '09en_US
dc.relation.ispartofconferencetitleJournal of Science and Medicine in Sporten_US
dc.relation.ispartofdatefrom2009-10-14en_US
dc.relation.ispartofdateto2010-03-17en_US
dc.relation.ispartoflocationBrisbaneen_US
dc.rights.retentionYen_AU
dc.subject.fieldofresearchBiomedical Instrumentationen_US
dc.subject.fieldofresearchcode090303en_US
dc.titleWearable Sensors for the Monitoring of Bowling Action in Cricketen_US
dc.typeConference outputen_US
dc.type.descriptionE3 - Conference Publications (Extract Paper)en_US
dc.type.codeE - Conference Publicationsen_US
gro.facultyGriffith Sciences, Griffith School of Engineeringen_US
gro.date.issued2009
gro.hasfulltextNo Full Text


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

  • Conference outputs
    Contains papers delivered by Griffith authors at national and international conferences.

Show simple item record