Show simple item record

dc.contributor.authorAmra, Ismailen_US
dc.contributor.authorSamsodien, Gilmieen_US
dc.contributor.authorShaikh, Amenahen_US
dc.contributor.authorLalloo, Ratilalen_US
dc.date.accessioned2017-05-03T11:46:43Z
dc.date.available2017-05-03T11:46:43Z
dc.date.issued2007en_US
dc.date.modified2010-07-26T06:49:47Z
dc.identifier.issn08895406en_US
dc.identifier.doi10.1016/j.ajodo.2006.06.013en_AU
dc.identifier.urihttp://hdl.handle.net/10072/32567
dc.description.abstractIntroduction: The newer single-step self-etching adhesives that etch, prime, and apply the resin bonding agent simultaneously without rinsing have been increasing in popularity in orthodontic bonding. The purpose of this study was to compare the bond strengths and to evaluate the debonding site (with the adhesive remnant index), when a conventional acid-etch conditioner and a self-etching adhesive system (Xeno III, Dentsply DeTrey GmbH, Konstanz, Germany) were used with either a composite resin adhesive (Transbond XT, 3M Unitek, Monrovia, Calif) or a resin-modified glass ionomer cement (Fuji Ortho LC, GC Corp, Tokyo, Japan). Methods: One hundred twenty extracted human premolars were mounted in acrylic resin and randomly assigned to 6 groups of 20 teeth each. Shear-peel bond strength testing was performed after thermocycling (5í55àfor 500 times) with a Zwick 1440 compression machine (Zwick, Ulm, Germany). Results: The results showed that the bond strengths achieved with Xeno III were comparable with the traditional methods of either 37% phosphoric acid or 10% polyacrylic acid for both Transbond XT and Fuji Ortho LC. Adhesive remnant index scores showed less adhesive remaining on the tooth surface in the Xeno III/Transbond XT adhesive only (no primer) group. Conclusions: Xeno III can be used to bond orthodontic brackets with the adhesives in this study.en_US
dc.description.peerreviewedYesen_US
dc.description.publicationstatusYesen_AU
dc.languageEnglishen_US
dc.language.isoen_AU
dc.publisherMosby, Inc.en_US
dc.publisher.placeUnited Statesen_US
dc.relation.ispartofstudentpublicationNen_AU
dc.relation.ispartofpagefrom160.e11en_US
dc.relation.ispartofpageto160.315en_US
dc.relation.ispartofissue2en_US
dc.relation.ispartofjournalAmerican Journal of Orthodontics and Dentofacial Orthopedicsen_US
dc.relation.ispartofvolume131en_US
dc.rights.retentionYen_AU
dc.subject.fieldofresearchDentistry not elsewhere classifieden_US
dc.subject.fieldofresearchcode110599en_US
dc.titleXeno III self-etching adhesive in orthodontic bonding: The next generationen_US
dc.typeJournal articleen_US
dc.type.descriptionC1 - Peer Reviewed (HERDC)en_US
dc.type.codeC - Journal Articlesen_US
gro.date.issued2007
gro.hasfulltextNo Full Text


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

  • Journal articles
    Contains articles published by Griffith authors in scholarly journals.

Show simple item record