Show simple item record

dc.contributor.authorGrobler, Sias R.en_US
dc.contributor.authorRossouw, Roelof J.en_US
dc.contributor.authorOberholzer, Theunis G.en_US
dc.date.accessioned2017-05-03T15:52:10Z
dc.date.available2017-05-03T15:52:10Z
dc.date.issued2007en_US
dc.date.modified2010-08-13T07:23:43Z
dc.identifier.issn00336572en_US
dc.identifier.urihttp://hdl.handle.net/10072/33428
dc.description.abstractThis study investigated the microleakage, etching ability, and dentin-restorative interface of 2 different single-step self-etching bonding agents with compomers as restoratives. METHOD AND MATERIALS: Fifteen extracted noncarious human premolars were used for each dental material system. The bonding agent Xeno III was used with their compomer Dyract AP (Dentsply) and Adper Prompt L-Pop with their compomer Z2000 (3M Espe). Cylindrical cavities were prepared in enamel and dentin on the buccal surface at the cementoenamel junction and restored. The specimens were thermocycled and cut into slices, and the depth of dye penetration scored. The dentine-restorative interface was examined through a confocal scanning laser microscope. RESULTS: Microleakages between the enamel and dentin sides differed significantly for Xeno (Wilcoxon rank sum test; P = .0058) as well as for Prompt (P = .0106), while the microleakages between the dentin sides of Xeno and Prompt did not differ significantly. However, between the enamel sides, a significant difference was found (P = .000), with the highest value for Prompt. The confocal laser studies showed tag formation, penetration of the bonding agents deep into the tubules, and hybrid layer formation for both bonding agents. CONCLUSIONS: It can be concluded that both adhesives gave microleakage values for dentin that are on the lower side. However, careful inspection of the enamel side indicated that both cannot be recommended for enamel sealing.en_US
dc.description.peerreviewedYesen_US
dc.description.publicationstatusYesen_AU
dc.languageEnglishen_US
dc.language.isoen_AU
dc.publisherQuintessenz Verlags-GmbHen_US
dc.publisher.placeGermanyen_US
dc.publisher.urihttp://www.quintpub.com/journals/qi/abstract.php?iss2_id=238&article_id=2847&article=20&title=Microleakage and confocal laser studies of 2 single-step self-etching bonding agents/systemsen_AU
dc.relation.ispartofstudentpublicationNen_AU
dc.relation.ispartofpagefrome334en_US
dc.relation.ispartofpagetoe341en_US
dc.relation.ispartofissue6en_US
dc.relation.ispartofjournalQuintessence Internationalen_US
dc.relation.ispartofvolume38en_US
dc.rights.retentionYen_AU
dc.subject.fieldofresearchDentistry not elsewhere classifieden_US
dc.subject.fieldofresearchcode110599en_US
dc.titleMicroleakage and confocal laser studies of 2 single-step self-etching bonding agents/systemsen_US
dc.typeJournal articleen_US
dc.type.descriptionC1 - Peer Reviewed (HERDC)en_US
dc.type.codeC - Journal Articlesen_US
gro.date.issued2007
gro.hasfulltextNo Full Text


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

  • Journal articles
    Contains articles published by Griffith authors in scholarly journals.

Show simple item record