Show simple item record

dc.contributor.authorLu, Xinzheng
dc.contributor.authorLi, Yi
dc.contributor.authorGuan, Hong
dc.contributor.authorYing, Mingjian
dc.date.accessioned2017-06-09T01:15:14Z
dc.date.available2017-06-09T01:15:14Z
dc.date.issued2017
dc.identifier.issn0015-2684
dc.identifier.doi10.1007/s10694-016-0566-6
dc.identifier.urihttp://hdl.handle.net/10072/339403
dc.description.abstractA number of disastrous incidents have indicated that extreme fires can act as a trigger event to initiate the progressive collapse of reinforced concrete (RC) structures. Hence, research on progressive collapse risks of RC structures under extreme fires is most important. However, limited studies have been undertaken in the fire-induced progressive collapse of tall and super-tall RC buildings. Hence, a high-performance finite element model was developed for this study to simulate the mechanical behavior of RC members in fire-induced progressive collapse. Fiber beam and multi-layer shell elements were used, in conjunction with appropriate material constitutive laws and elemental failure criteria under high temperature conditions. Extreme fire scenarios were also considered, based on the actual fire-induced progressive collapse events of the WTC towers and the Windsor Tower. The simulation results indicated that a progressive collapse of a super-tall building was triggered by the flexural failure of the peripheral columns, approximately 7 h after being exposed to fire. The bending deformations of the peripheral columns increased significantly, due to the outward thermal expansion of the upper floors and the inward contraction of the lower floors, a result of the fire-induced damage. The results also revealed that, when multiple stories are subjected to fire, the internal forces in the components are redistributed in the horizontal and vertical directions by way of the Vierendeel truss mechanism, leading to a maximum increase (of approximately 100%) of the axial forces in the columns. The present work identified the mechanisms of the fire-induced progressive collapse of a typical RC super-tall building, and provided an effective analysis framework for further research on the fire safety of tall and super-tall RC buildings.
dc.description.peerreviewedYes
dc.languageEnglish
dc.publisherSpringer
dc.relation.ispartofpagefrom107
dc.relation.ispartofpageto133
dc.relation.ispartofissue1
dc.relation.ispartofjournalFire Technology
dc.relation.ispartofvolume53
dc.subject.fieldofresearchCivil Engineering not elsewhere classified
dc.subject.fieldofresearchEngineering
dc.subject.fieldofresearchcode090599
dc.subject.fieldofresearchcode09
dc.titleProgressive Collapse Analysis of a Typical Super-Tall Reinforced Concrete Frame-Core Tube Building Exposed to Extreme Fires
dc.typeJournal article
dc.type.descriptionC1 - Articles
dc.type.codeC - Journal Articles
gro.hasfulltextNo Full Text
gro.griffith.authorGuan, Hong


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

  • Journal articles
    Contains articles published by Griffith authors in scholarly journals.

Show simple item record