Non-invasive assessment of sciatic nerve stiffness during human ankle motion using ultrasound shear wave elastography
Author(s)
Andrade, Ricardo J
Nordez, Antoine
Hug, Francois
Ates, Filiz
Coppieters, Michel W
Pezarat-Correia, Pedro
Freitas, Sandro R
Griffith University Author(s)
Year published
2016
Metadata
Show full item recordAbstract
Peripheral nerves are exposed to mechanical stress during movement. However the in vivo mechanical properties of nerves remain largely unexplored. The primary aim of this study was to characterize the effect of passive dorsiflexion on sciatic nerve shear wave velocity (an index of stiffness) when the knee was in 90° flexion (knee 90°) or extended (knee 180°). The secondary aim was to determine the effect of five repeated dorsiflexions on the nerve shear wave velocity. Nine healthy participants were tested. The repeatability of sciatic nerve shear wave velocity was good for both knee 90° and knee 180° (ICCs≥0.92, CVs≤8.1%). ...
View more >Peripheral nerves are exposed to mechanical stress during movement. However the in vivo mechanical properties of nerves remain largely unexplored. The primary aim of this study was to characterize the effect of passive dorsiflexion on sciatic nerve shear wave velocity (an index of stiffness) when the knee was in 90° flexion (knee 90°) or extended (knee 180°). The secondary aim was to determine the effect of five repeated dorsiflexions on the nerve shear wave velocity. Nine healthy participants were tested. The repeatability of sciatic nerve shear wave velocity was good for both knee 90° and knee 180° (ICCs≥0.92, CVs≤8.1%). The shear wave velocity of the sciatic nerve significantly increased (p<0.0001) during dorsiflexion when the knee was extended (knee 180°), but no changes were observed when the knee was flexed (90°). The shear wave velocity–angle relationship displayed a hysteresis for knee 180°. Although there was a tendency for the nerve shear wave velocity to decrease throughout the repetition of the five ankle dorsiflexions, the level of significance was not reached (p=0.055). These results demonstrate that the sciatic nerve stiffness can be non-invasively assessed during passive movements. In addition, the results highlight the importance of considering both the knee and the ankle position for clinical and biomechanical assessment of the sciatic nerve. This non-invasive technique offers new perspectives to provide new insights into nerve mechanics in both healthy and clinical populations (e.g., specific peripheral neuropathies).
View less >
View more >Peripheral nerves are exposed to mechanical stress during movement. However the in vivo mechanical properties of nerves remain largely unexplored. The primary aim of this study was to characterize the effect of passive dorsiflexion on sciatic nerve shear wave velocity (an index of stiffness) when the knee was in 90° flexion (knee 90°) or extended (knee 180°). The secondary aim was to determine the effect of five repeated dorsiflexions on the nerve shear wave velocity. Nine healthy participants were tested. The repeatability of sciatic nerve shear wave velocity was good for both knee 90° and knee 180° (ICCs≥0.92, CVs≤8.1%). The shear wave velocity of the sciatic nerve significantly increased (p<0.0001) during dorsiflexion when the knee was extended (knee 180°), but no changes were observed when the knee was flexed (90°). The shear wave velocity–angle relationship displayed a hysteresis for knee 180°. Although there was a tendency for the nerve shear wave velocity to decrease throughout the repetition of the five ankle dorsiflexions, the level of significance was not reached (p=0.055). These results demonstrate that the sciatic nerve stiffness can be non-invasively assessed during passive movements. In addition, the results highlight the importance of considering both the knee and the ankle position for clinical and biomechanical assessment of the sciatic nerve. This non-invasive technique offers new perspectives to provide new insights into nerve mechanics in both healthy and clinical populations (e.g., specific peripheral neuropathies).
View less >
Journal Title
Journal of Biomechanics
Volume
49
Issue
3
Subject
Biomedical engineering
Mechanical engineering
Sports science and exercise
Sports science and exercise not elsewhere classified