Chlorhexidine gluconate or polyhexamethylene biguanide disc dressing to reduce the incidence of central-line-associated bloodstream infection: a feasibility randomized controlled trial (the CLABSI trial)

View/ Open
File version
Accepted Manuscript (AM)
Author(s)
Webster, J
Larsen, E
Marsh, N
Choudhury, A
Harris, P
Rickard, CM
Griffith University Author(s)
Year published
2017
Metadata
Show full item recordAbstract
Background: A number of antimicrobial-impregnated discs to prevent central-lineassociated
bloodstream infection (CLABSI) are marketed but it is unclear which disc is
most effective.
Aim: To investigate the feasibility and safety of comparing two antimicrobial-impregnated
discs to prevent CLABSI.
Methods: A single-centre, parallel group, randomized controlled trial was conducted in a
929-bed tertiary referral hospital. Hospital inpatients requiring a peripherally inserted
central catheter were randomized to chlorhexidine gluconate (CHG) or polyhexamethylene
biguanide (PHMB) disc dressing group. Dressings were replaced every ...
View more >Background: A number of antimicrobial-impregnated discs to prevent central-lineassociated bloodstream infection (CLABSI) are marketed but it is unclear which disc is most effective. Aim: To investigate the feasibility and safety of comparing two antimicrobial-impregnated discs to prevent CLABSI. Methods: A single-centre, parallel group, randomized controlled trial was conducted in a 929-bed tertiary referral hospital. Hospital inpatients requiring a peripherally inserted central catheter were randomized to chlorhexidine gluconate (CHG) or polyhexamethylene biguanide (PHMB) disc dressing group. Dressings were replaced every seven days, or earlier, if clinically required. Participants were followed until device removal or hospital discharge. Feasibility outcomes included: proportion of potentially eligible participants who were enrolled; proportion of protocol violations; and proportion of patients lost to follow-up. Clinical outcomes were: CLABSI incidence, diagnosed by a blinded infection control practitioner; all-cause bloodstream infection (BSI); and product-related adverse events. Findings: Of 143 patients screened, 101 (71%) were eligible. Five (3.5%) declined participation. There was one post-randomization exclusion. Two (2%) protocol violations occurred in the CHG group. No patients were lost to follow-up. Three (3%) BSIs occurred; two (2%) were confirmed CLABSIs (one in each group) and one a mucosal barrier injuryrelated BSI. A total of 1217 device-days were studied, resulting in 1.64 CLABSIs per 1000 catheter-days. One (1%) disc-related adverse event occurred in the CHG group. Conclusion: Disc dressings containing PHMB are safe to use for infection prevention at catheter insertion sites. An adequately powered trial to compare PHMB and CHG discs is feasible
View less >
View more >Background: A number of antimicrobial-impregnated discs to prevent central-lineassociated bloodstream infection (CLABSI) are marketed but it is unclear which disc is most effective. Aim: To investigate the feasibility and safety of comparing two antimicrobial-impregnated discs to prevent CLABSI. Methods: A single-centre, parallel group, randomized controlled trial was conducted in a 929-bed tertiary referral hospital. Hospital inpatients requiring a peripherally inserted central catheter were randomized to chlorhexidine gluconate (CHG) or polyhexamethylene biguanide (PHMB) disc dressing group. Dressings were replaced every seven days, or earlier, if clinically required. Participants were followed until device removal or hospital discharge. Feasibility outcomes included: proportion of potentially eligible participants who were enrolled; proportion of protocol violations; and proportion of patients lost to follow-up. Clinical outcomes were: CLABSI incidence, diagnosed by a blinded infection control practitioner; all-cause bloodstream infection (BSI); and product-related adverse events. Findings: Of 143 patients screened, 101 (71%) were eligible. Five (3.5%) declined participation. There was one post-randomization exclusion. Two (2%) protocol violations occurred in the CHG group. No patients were lost to follow-up. Three (3%) BSIs occurred; two (2%) were confirmed CLABSIs (one in each group) and one a mucosal barrier injuryrelated BSI. A total of 1217 device-days were studied, resulting in 1.64 CLABSIs per 1000 catheter-days. One (1%) disc-related adverse event occurred in the CHG group. Conclusion: Disc dressings containing PHMB are safe to use for infection prevention at catheter insertion sites. An adequately powered trial to compare PHMB and CHG discs is feasible
View less >
Journal Title
Journal of Hospital Infection
Volume
96
Issue
3
Copyright Statement
© 2017 The Healthcare Infection Society. Published by Elsevier. Licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International (http://creativecommons.org/licenses/by-nc-nd/4.0/) which permits unrestricted, non-commercial use, distribution and reproduction in any medium, providing that the work is properly cited.
Subject
Clinical sciences
Health services and systems
Public health