Show simple item record

dc.contributor.authorRantalainen, Timo
dc.contributor.authorChivers, Paola
dc.contributor.authorBeck, Belinda R
dc.contributor.authorRobertson, Sam
dc.contributor.authorHart, Nicolas H
dc.contributor.authorNimphius, Sophia
dc.contributor.authorWeeks, Benjamin K
dc.contributor.authorMcIntyre, Fleur
dc.contributor.authorHands, Beth
dc.contributor.authorSiafarikas, Aris
dc.date.accessioned2017-11-15T23:10:42Z
dc.date.available2017-11-15T23:10:42Z
dc.date.issued2018
dc.identifier.issn1094-6950
dc.identifier.doi10.1016/j.jocd.2017.07.002
dc.identifier.urihttp://hdl.handle.net/10072/352677
dc.description.abstractMost imaging methods, including peripheral quantitative computed tomography (pQCT), are susceptible to motion artifacts particularly in fidgety pediatric populations. Methods currently used to address motion artifact include manual screening (visual inspection) and objective assessments of the scans. However, previously reported objective methods either cannot be applied on the reconstructed image or have not been tested for distal bone sites. Therefore, the purpose of the present study was to develop and validate motion artifact classifiers to quantify motion artifact in pQCT scans. Whether textural features could provide adequate motion artifact classification performance in 2 adolescent datasets with pQCT scans from tibial and radial diaphyses and epiphyses was tested. The first dataset was split into training (66% of sample) and validation (33% of sample) datasets. Visual classification was used as the ground truth. Moderate to substantial classification performance (J48 classifier, kappa coefficients from 0.57 to 0.80) was observed in the validation dataset with the novel texture-based classifier. In applying the same classifier to the second cross-sectional dataset, a slight-to-fair (κ = 0.01–0.39) classification performance was observed. Overall, this novel textural analysis-based classifier provided a moderate-to-substantial classification of motion artifact when the classifier was specifically trained for the measurement device and population. Classification based on textural features may be used to prescreen obviously acceptable and unacceptable scans, with a subsequent human-operated visual classification of any remaining scans.
dc.description.peerreviewedYes
dc.languageEnglish
dc.language.isoeng
dc.publisherElsevier
dc.relation.ispartofpagefrom1
dc.relation.ispartofpageto9
dc.relation.ispartofjournalJournal of Clinical Densitometry
dc.subject.fieldofresearchClinical Sciences not elsewhere classified
dc.subject.fieldofresearchClinical Sciences
dc.subject.fieldofresearchcode110399
dc.subject.fieldofresearchcode1103
dc.titlePlease Don't Move-Evaluating Motion Artifact From Peripheral Quantitative Computed Tomography Scans Using Textural Features
dc.typeJournal article
dc.type.descriptionC1 - Articles
dc.type.codeC - Journal Articles
gro.description.notepublicThis publication has been entered into Griffith Research Online as an Advanced Online Version.
gro.hasfulltextNo Full Text
gro.griffith.authorBeck, Belinda R.
gro.griffith.authorWeeks, Benjamin K.


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

  • Journal articles
    Contains articles published by Griffith authors in scholarly journals.

Show simple item record