dc.description.abstractConventional high frequency power transformers are configured without protection to avoid parasitic effects. Therefore this paper presents and investigates a FEM technique and measurement results for planar and coaxial high frequency power transformers used for DC/DC converters in photo voltaic (PV) power systems. The winding structure includes a Faraday shield between the primary and secondary windings and is designed to minimize skin and proximity effects, eddy current losses, the leakage inductance, and the inter winding coupling capacitance. Finite Element Method is employed to analyze the magnetic flux and eddy current distributions, and to accurately calculate the intra- and inter- winding capacitances based on the theory of capacitances in a multi-conductor electro-magnetic system. The two different kinds of HF transformers have been tested and experimentally simulated. The measured results demonstrate, in contrast to non shielded transformers, that the shielded transformers have achieved the expected results with a relatively small coupling capacitance, compared with the conventional high frequency transformer. This shield decreases the inter-winding coupling capacitance Cps and the leakage induction.
dc.description.peerreviewedYes
dc.description.publicationstatusYes
dc.format.extent1499358 bytes
dc.format.mimetypeapplication/pdf
dc.languageEnglish
dc.language.isoeng
dc.publisherIEEE
dc.publisher.placeBeijing
dc.relation.ispartofstudentpublicationY
dc.relation.ispartofconferencenameAsia-Pacific International Symposium on Electromagnetic Compatibility / Technical Exhibition on EMC RFIMicrowave Measurements and Instrumentation
dc.relation.ispartofconferencetitle2010 ASIA-PACIFIC INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY & TECHNICAL EXHIBITION ON EMC RF/MICROWAVE MEASUREMENTS & INSTRUMENTATION
dc.relation.ispartofdatefrom2010-04-12
dc.relation.ispartofdateto2010-04-16
dc.relation.ispartoflocationBeijing, PEOPLES R CHINA
dc.relation.ispartofpagefrom414
dc.relation.ispartofpagefrom4 pages
dc.relation.ispartofpageto417
dc.relation.ispartofpageto4 pages
dc.rights.retentionY
dc.subject.fieldofresearchElectrical and Electronic Engineering not elsewhere classified
dc.subject.fieldofresearchcode090699
dc.titleShielding Effect of High Frequency Power Transformers for DC/DC Converters used in Solar PV Systems
dc.typeConference output
dc.type.descriptionE1 - Conferences
dc.type.codeE - Conference Publications
gro.facultyGriffith Sciences, Griffith School of Engineering
gro.rights.copyright© 2010 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE.
gro.date.issued2010
gro.hasfulltextFull Text
gro.griffith.authorLu, Junwei
gro.griffith.authorStegen, Sascha


Files in this item