From insertion to removal: A multicenter survival analysis of an admitted cohort with peripheral intravenous catheters inserted in the emergency department
Author(s)
Carr, Peter J
Rippey, James CR
Cooke, Marie L
Higgins, Niall S
Trevenen, Michelle
Foale, Aileen
Rickard, Claire M
Griffith University Author(s)
Year published
2018
Metadata
Show full item recordAbstract
Background:
Most patients admitted to the hospital via the emergency department (ED) do so with a peripheral intravenous catheter/cannula (PIVC). Many PIVCs develop postinsertion failure (PIF).
Objective:
To determine the independent factors predicting PIF after PIVC insertion in the ED.
Methods:
We analyzed data from a prospective clinical cohort study of ED-inserted PIVCs admitted to the hospital wards. Independent predictors of PIF were identified using Cox proportional hazards regression modeling.
Results:
In 391 patients admitted from 2 EDs, the rate of PIF was 31% (n=118). The types of PIF identified were infiltration, ...
View more >Background: Most patients admitted to the hospital via the emergency department (ED) do so with a peripheral intravenous catheter/cannula (PIVC). Many PIVCs develop postinsertion failure (PIF). Objective: To determine the independent factors predicting PIF after PIVC insertion in the ED. Methods: We analyzed data from a prospective clinical cohort study of ED-inserted PIVCs admitted to the hospital wards. Independent predictors of PIF were identified using Cox proportional hazards regression modeling. Results: In 391 patients admitted from 2 EDs, the rate of PIF was 31% (n=118). The types of PIF identified were infiltration, occlusion, pain and/or peripheral intravenous assessment score >2 (ie, the hospital’s assessment of PIVC phlebitis), and dislodgement (ie, accidental securement device failure or purposeful removal). Of the PIVCs that failed, infiltration and occlusion combined were the most common causes of PIF (n=55, 47%). The median PIVC dwell time was 28.5 hours (interquartile range [IQR], 17.4–50.8 hours). The following variables were associated with increased risk of PIF: being an older patient (for a 1-year increase, hazard ratio [HR], 1.02; 95% confidence interval [CI], 1.01–1.03; P=.0001); having an Australian Triage Scale score of 1 or 2 compared to a score of 3, 4, or 5 (HR, 2.04; 95% CI, 1.39–3.01; P=.0003); having an ultrasound-guided PIVC (HR, 6.52; 95% CI, 2.11–20.1; P=.0011); having the PIVC inserted by a medical student (P=.0095); infection prevention breaches at insertion (P=.0326); and PIVC inserted in the ante cubital fossa or the back of hand compared to the upper arm (P=.0337). Conclusion: PIF remains at an unacceptable level in both traditionally inserted and ultrasound-inserted PIVCs.
View less >
View more >Background: Most patients admitted to the hospital via the emergency department (ED) do so with a peripheral intravenous catheter/cannula (PIVC). Many PIVCs develop postinsertion failure (PIF). Objective: To determine the independent factors predicting PIF after PIVC insertion in the ED. Methods: We analyzed data from a prospective clinical cohort study of ED-inserted PIVCs admitted to the hospital wards. Independent predictors of PIF were identified using Cox proportional hazards regression modeling. Results: In 391 patients admitted from 2 EDs, the rate of PIF was 31% (n=118). The types of PIF identified were infiltration, occlusion, pain and/or peripheral intravenous assessment score >2 (ie, the hospital’s assessment of PIVC phlebitis), and dislodgement (ie, accidental securement device failure or purposeful removal). Of the PIVCs that failed, infiltration and occlusion combined were the most common causes of PIF (n=55, 47%). The median PIVC dwell time was 28.5 hours (interquartile range [IQR], 17.4–50.8 hours). The following variables were associated with increased risk of PIF: being an older patient (for a 1-year increase, hazard ratio [HR], 1.02; 95% confidence interval [CI], 1.01–1.03; P=.0001); having an Australian Triage Scale score of 1 or 2 compared to a score of 3, 4, or 5 (HR, 2.04; 95% CI, 1.39–3.01; P=.0003); having an ultrasound-guided PIVC (HR, 6.52; 95% CI, 2.11–20.1; P=.0011); having the PIVC inserted by a medical student (P=.0095); infection prevention breaches at insertion (P=.0326); and PIVC inserted in the ante cubital fossa or the back of hand compared to the upper arm (P=.0337). Conclusion: PIF remains at an unacceptable level in both traditionally inserted and ultrasound-inserted PIVCs.
View less >
Journal Title
Infection Control & Hospital Epidemiology
Volume
39
Issue
10
Subject
Biomedical and clinical sciences
Acute care