Loading characteristics data applied on osseointegrated implant by transfemoral bone-anchored prostheses fitted with basic components during daily activities

View/ Open
File version
Version of Record (VoR)
Author(s)
Frossard, L
Griffith University Author(s)
Year published
2019
Metadata
Show full item recordAbstract
The data in this paper are related to the research articles entitled “Kinetics of transfemoral amputees with osseointegrated fixation performing common activities of daily living” (Lee et al., Clinical Biomechanics, 2007.22(6). p. 665–673) and “Magnitude and variability of loading on the osseointegrated implant of transfemoral amputees during walking” (Lee et al., Med Eng Phys, 2008.30(7). p. 825–833). This article contains the overall and individual loading characteristics applied on screw-type osseointegrated implant generated by transfemoral bone-anchored prostheses fitted with basic components during daily activities at ...
View more >The data in this paper are related to the research articles entitled “Kinetics of transfemoral amputees with osseointegrated fixation performing common activities of daily living” (Lee et al., Clinical Biomechanics, 2007.22(6). p. 665–673) and “Magnitude and variability of loading on the osseointegrated implant of transfemoral amputees during walking” (Lee et al., Med Eng Phys, 2008.30(7). p. 825–833). This article contains the overall and individual loading characteristics applied on screw-type osseointegrated implant generated by transfemoral bone-anchored prostheses fitted with basic components during daily activities at self-selected comfortable pace. Overall and individual data was presented for the (A) spatio-temporal characteristics, (B) loading patterns, (C) loading boundaries and (D) the loading local extremum during level walking, ascending and descending ramp and stairs. Inter-participant variability of these new datasets with basic components is critical to improve the efficacy and safety of prosthetic components as well as the design of future automated algorithms and clinical trials. Online repository contains the files: https://data.mendeley.com/datasets/hh8rjjh73w/1.
View less >
View more >The data in this paper are related to the research articles entitled “Kinetics of transfemoral amputees with osseointegrated fixation performing common activities of daily living” (Lee et al., Clinical Biomechanics, 2007.22(6). p. 665–673) and “Magnitude and variability of loading on the osseointegrated implant of transfemoral amputees during walking” (Lee et al., Med Eng Phys, 2008.30(7). p. 825–833). This article contains the overall and individual loading characteristics applied on screw-type osseointegrated implant generated by transfemoral bone-anchored prostheses fitted with basic components during daily activities at self-selected comfortable pace. Overall and individual data was presented for the (A) spatio-temporal characteristics, (B) loading patterns, (C) loading boundaries and (D) the loading local extremum during level walking, ascending and descending ramp and stairs. Inter-participant variability of these new datasets with basic components is critical to improve the efficacy and safety of prosthetic components as well as the design of future automated algorithms and clinical trials. Online repository contains the files: https://data.mendeley.com/datasets/hh8rjjh73w/1.
View less >
Journal Title
Data in Brief
Volume
26
Copyright Statement
© 2019 The Author(s). Published by Elsevier Inc. This is an open access article under the CC BY-NC-ND license (http:// creativecommons.org/licenses/by-nc-nd/4.0/) which permits unrestricted, non-commercial use, distribution and reproduction in any medium, providing that the work is properly cited.
Subject
Clinical sciences
Amputation
Artificial limb
Bone-anchored prosthesis (BAP)
Direct skeletal attachment
Kinetics