68Ga-PSMA PET/CT better characterises localised prostate cancer after MRI and transperineal prostate biopsy: Is 68Ga-PSMA PET/CT guided biopsy the future?
Author(s)
Donato, Peter
Morton, Andrew
Yaxley, John
Ranasinghe, Sachinka
Teloken, Patrick E
Kyle, Samuel
Coughlin, Geoff
Esler, Rachel
Dunglison, Nigel
Gardiner, Robert A
Roberts, Matthew J
Griffith University Author(s)
Year published
2020
Metadata
Show full item recordAbstract
BACKGROUND: 68Ga prostate specific membrane antigen PET/CT (68Ga-PSMA PET/CT) may be superior to multiparametric MRI (mpMRI) for localisation of prostate cancer tumour foci, however the concordance and differences between 68Ga-PSMA PET/CT and mpMRI when applied to all biopsied patients and potential benefit in patients with negative mpMRI is unclear. METHODS: Retrospective analysis of patients undergoing mpMRI, prostate biopsy and 68Ga-PSMA PET/CT over a 3-year period. Diagnostic performance of 68Ga-PSMA PET/CT and mpMRI were assessed using biopsy histopathology for the entire cohort and radical prostatectomy specimen in a ...
View more >BACKGROUND: 68Ga prostate specific membrane antigen PET/CT (68Ga-PSMA PET/CT) may be superior to multiparametric MRI (mpMRI) for localisation of prostate cancer tumour foci, however the concordance and differences between 68Ga-PSMA PET/CT and mpMRI when applied to all biopsied patients and potential benefit in patients with negative mpMRI is unclear. METHODS: Retrospective analysis of patients undergoing mpMRI, prostate biopsy and 68Ga-PSMA PET/CT over a 3-year period. Diagnostic performance of 68Ga-PSMA PET/CT and mpMRI were assessed using biopsy histopathology for the entire cohort and radical prostatectomy specimen in a subset of patients. Lesion concordance and additional detection of each modality were determined, including in a dedicated cohort of patients with mpMRI PIRADS 2 scans. RESULTS: A total of 144 patients were included in the study. Index lesion/foci detection was similar between 68Ga-PSMA PET/CT and mpMRI (sensitivity 83.1% vs 90.1%; p = 0.267), however lesions missed by mpMRI were larger (1.66 cm3 vs 0.72 cm3; p = 0.034). Lesion detection rates were similar across the biopsy histopathology and radical prostatectomy specimen subset, with a high concordance for index (80.1%) and a moderate concordance for total (67%) lesions between the 2 imaging modalities. The additional detection yield favoured 68Ga-PSMA PET/CT over mpMRI for index (13.5% vs 4.3%) and total (18.2% vs 5.4%) lesions; both modalities missed 2.1% and 12.3% of index and total lesions, respectively. 68Ga-PSMA PET/CT identified 9 of 11 patients with PIRADS 2 mpMRI but subsequently diagnosed with Gleason ≥ 3 + 4 disease. CONCLUSIONS: Despite high concordance rates, 68Ga-PSMA PET/CT incrementally improved tumour localisation compared with mpMRI. These results suggest that 68Ga-PSMA PET/CT may have an incremental value to that of mpMRI in the diagnostic process for prostate.
View less >
View more >BACKGROUND: 68Ga prostate specific membrane antigen PET/CT (68Ga-PSMA PET/CT) may be superior to multiparametric MRI (mpMRI) for localisation of prostate cancer tumour foci, however the concordance and differences between 68Ga-PSMA PET/CT and mpMRI when applied to all biopsied patients and potential benefit in patients with negative mpMRI is unclear. METHODS: Retrospective analysis of patients undergoing mpMRI, prostate biopsy and 68Ga-PSMA PET/CT over a 3-year period. Diagnostic performance of 68Ga-PSMA PET/CT and mpMRI were assessed using biopsy histopathology for the entire cohort and radical prostatectomy specimen in a subset of patients. Lesion concordance and additional detection of each modality were determined, including in a dedicated cohort of patients with mpMRI PIRADS 2 scans. RESULTS: A total of 144 patients were included in the study. Index lesion/foci detection was similar between 68Ga-PSMA PET/CT and mpMRI (sensitivity 83.1% vs 90.1%; p = 0.267), however lesions missed by mpMRI were larger (1.66 cm3 vs 0.72 cm3; p = 0.034). Lesion detection rates were similar across the biopsy histopathology and radical prostatectomy specimen subset, with a high concordance for index (80.1%) and a moderate concordance for total (67%) lesions between the 2 imaging modalities. The additional detection yield favoured 68Ga-PSMA PET/CT over mpMRI for index (13.5% vs 4.3%) and total (18.2% vs 5.4%) lesions; both modalities missed 2.1% and 12.3% of index and total lesions, respectively. 68Ga-PSMA PET/CT identified 9 of 11 patients with PIRADS 2 mpMRI but subsequently diagnosed with Gleason ≥ 3 + 4 disease. CONCLUSIONS: Despite high concordance rates, 68Ga-PSMA PET/CT incrementally improved tumour localisation compared with mpMRI. These results suggest that 68Ga-PSMA PET/CT may have an incremental value to that of mpMRI in the diagnostic process for prostate.
View less >
Journal Title
European Journal of Nuclear Medicine and Molecular Imaging
Note
This publication has been entered into Griffith Research Online as an Advanced Online Version
Subject
Other physical sciences
Clinical sciences
Glutamate carboxypeptidase II
Human
Magnetic resonance imaging
Positron-emission tomography
Prostate specific membrane antigen