Show simple item record

dc.contributor.authorHe, Congrong
dc.contributor.authorMackay, Ian M
dc.contributor.authorRamsay, Kay
dc.contributor.authorLiang, Zhen
dc.contributor.authorKidd, Timothy
dc.contributor.authorKnibbs, Luke D
dc.contributor.authorJohnson, Graham
dc.contributor.authorMcNeale, Donna
dc.contributor.authorStockwelle, Rebecca
dc.contributor.authorCoulthard, Mark G
dc.contributor.authorLong, Debbie A
dc.contributor.authorWilliams, Tara J
dc.contributor.authorDuchaine, Caroline
dc.contributor.authorSmith, Natalie
dc.contributor.authorWainwright, Claire
dc.contributor.authorMorawska, Lidia
dc.date.accessioned2020-02-10T03:35:06Z
dc.date.available2020-02-10T03:35:06Z
dc.date.issued2017
dc.identifier.issn0160-4120
dc.identifier.doi10.1016/j.envint.2017.06.020
dc.identifier.urihttp://hdl.handle.net/10072/391272
dc.description.abstractThe paediatric intensive care unit (PICU) provides care to critically ill neonates, infants and children. These patients are vulnerable and susceptible to the environment surrounding them, yet there is little information available on indoor air quality and factors affecting it within a PICU. To address this gap in knowledge we conducted continuous indoor and outdoor airborne particle concentration measurements over a two-week period at the Royal Children's Hospital PICU in Brisbane, Australia, and we also collected 82 bioaerosol samples to test for the presence of bacterial and viral pathogens. Our results showed that both 24-hour average indoor particle mass (PM10) (0.6–2.2 μg m− 3, median: 0.9 μg m− 3) and submicrometer particle number (PN) (0.1–2.8 × 103 p cm− 3, median: 0.67 × 103 p cm− 3) concentrations were significantly lower (p < 0.01) than the outdoor concentrations (6.7–10.2 μg m− 3, median: 8.0 μg m− 3 for PM10 and 12.1–22.2 × 103 p cm− 3, median: 16.4 × 103 p cm− 3 for PN). In general, we found that indoor particle concentrations in the PICU were mainly affected by indoor particle sources, with outdoor particles providing a negligible background. We identified strong indoor particle sources in the PICU, which occasionally increased indoor PN and PM10 concentrations from 0.1 × 103 to 100 × 103 p cm− 3, and from 2 μg m− 3 to 70 μg m− 3, respectively. The most substantial indoor particle sources were nebulization therapy, tracheal suction and cleaning activities. The average PM10 and PN emission rates of nebulization therapy ranged from 1.29 to 7.41 mg min− 1 and from 1.20 to 3.96 p min− 1 × 1011, respectively. Based on multipoint measurement data, it was found that particles generated at each location could be quickly transported to other locations, even when originating from isolated single-bed rooms. The most commonly isolated bacterial genera from both primary and broth cultures were skin commensals while viruses were rarely identified. Based on the findings from the study, we developed a set of practical recommendations for PICU design, as well as for medical and cleaning staff to mitigate aerosol generation and transmission to minimize infection risk to PICU patients.
dc.description.peerreviewedYes
dc.languageEnglish
dc.language.isoeng
dc.publisherElsevier
dc.relation.ispartofpagefrom89
dc.relation.ispartofpageto99
dc.relation.ispartofjournalEnvironment International
dc.relation.ispartofvolume107
dc.subject.fieldofresearchPaediatrics
dc.subject.fieldofresearchcode3213
dc.subject.keywordsScience & Technology
dc.subject.keywordsLife Sciences & Biomedicine
dc.subject.keywordsEnvironmental Sciences
dc.subject.keywordsEnvironmental Sciences & Ecology
dc.subject.keywordsAirborne particle number and mass
dc.titleParticle and bioaerosol characteristics in a paediatric intensive care unit
dc.typeJournal article
dc.type.descriptionC1 - Articles
dcterms.bibliographicCitationHe, C; Mackay, IM; Ramsay, K; Liang, Z; Kidd, T; Knibbs, LD; Johnson, G; McNeale, D; Stockwelle, R; Coulthard, MG; Long, DA; Williams, TJ; Duchaine, C; Smith, N; Wainwright, C; Morawska, L, Particle and bioaerosol characteristics in a paediatric intensive care unit, Environment International, 2017, 107, pp. 89-99
dcterms.dateAccepted2017-06-26
dc.date.updated2020-02-10T03:33:50Z
gro.hasfulltextNo Full Text
gro.griffith.authorMcNeale, Donna


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

  • Journal articles
    Contains articles published by Griffith authors in scholarly journals.

Show simple item record