Show simple item record

dc.contributor.authorLoh, Tze Ping
dc.contributor.authorBietenbeck, Andreas
dc.contributor.authorCervinski, Mark A
dc.contributor.authorvan Rossum, Huub H
dc.contributor.authorKatayev, Alex
dc.contributor.authorBadrick, Tony
dc.date.accessioned2020-05-18T02:30:56Z
dc.date.available2020-05-18T02:30:56Z
dc.date.issued2020
dc.identifier.issn1434-6621
dc.identifier.doi10.1515/cclm-2019-1024
dc.identifier.urihttp://hdl.handle.net/10072/393930
dc.description.abstractPatient-based real-time quality control (PBRTQC) is a laboratory tool for monitoring the performance of the testing process. It includes well-established procedures like Bull's algorithm, average of nomals, moving median, moving average (MA) and exponentially (weighted) MAs. Following the setup and optimization processes, a key step prior to the routine implementation of PBRTQC is the verification and documentation of the performance of the PBRTQC as part of the laboratory quality system. This verification process should provide a realistic representation of the performance of the PBRTQC in the environment it is being implemented in, to allow proper risk assessment by laboratory practitioners. This document focuses on the recommendation on performance verification of PBRTQC prior to implementation.
dc.description.peerreviewedYes
dc.languageEnglish
dc.language.isoeng
dc.publisherWalter de Gruyter GmbH
dc.relation.ispartofjournalClinical Chemistry and Laboratory Medicine
dc.subject.fieldofresearchClinical Sciences
dc.subject.fieldofresearchCognitive Sciences
dc.subject.fieldofresearchcode1103
dc.subject.fieldofresearchcode1702
dc.subject.keywordsevaluation
dc.subject.keywordsmoving average
dc.subject.keywordsmoving median
dc.subject.keywordspatient-based quality control
dc.subject.keywordspatient-based real-time quality control
dc.titleRecommendation for performance verification of patient-based real-time quality control
dc.typeJournal article
dc.type.descriptionC1 - Articles
dcterms.bibliographicCitationLoh, TP; Bietenbeck, A; Cervinski, MA; Van Rossum, HH; Katayev, A; Badrick, T, Recommendation for performance verification of patient-based real-time quality control, Clinical Chemistry and Laboratory Medicine, 2020
dcterms.dateAccepted2020-01-13
dc.date.updated2020-05-18T02:26:38Z
dc.description.versionVersion of Record (VoR)
gro.rights.copyright© 2020 Walter de Gruyter & Co. KG Publishers. The attached file is reproduced here in accordance with the copyright policy of the publisher. Please refer to the journal's website for access to the definitive, published version.
gro.hasfulltextFull Text
gro.griffith.authorBadrick, Tony C.


Files in this item

This item appears in the following Collection(s)

  • Journal articles
    Contains articles published by Griffith authors in scholarly journals.

Show simple item record