• myGriffith
    • Staff portal
    • Contact Us⌄
      • Future student enquiries 1800 677 728
      • Current student enquiries 1800 154 055
      • International enquiries +61 7 3735 6425
      • General enquiries 07 3735 7111
      • Online enquiries
      • Staff phonebook
    View Item 
    •   Home
    • Griffith Research Online
    • Journal articles
    • View Item
    • Home
    • Griffith Research Online
    • Journal articles
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Browse

  • All of Griffith Research Online
    • Communities & Collections
    • Authors
    • By Issue Date
    • Titles
  • This Collection
    • Authors
    • By Issue Date
    • Titles
  • Statistics

  • Most Popular Items
  • Statistics by Country
  • Most Popular Authors
  • Support

  • Contact us
  • FAQs
  • Admin login

  • Login
  • The safety and efficacy of prolonged use of one-way speaking valves

    Author(s)
    O'Connor, LR
    Morris, N
    Paratz, J
    Griffith University Author(s)
    Morris, Norman
    Year published
    2020
    Metadata
    Show full item record
    Abstract
    Background: One-way speaking valves were first engineered to improve communication in patients with tracheostomies. More recently, additional indications for one-way speaking valves have been explored, including improving ventilation, weaning, and reducing aspiration; however, safety and adverse events have not been well defined. Objectives: The aim of this study was to examine the cardiorespiratory changes that occur with prolonged use of a one-way speaking valve in relation to safety and efficacy. Methods: A prospective observational study of adult patients (n = 20) was carried out in a tertiary level intensive care unit. ...
    View more >
    Background: One-way speaking valves were first engineered to improve communication in patients with tracheostomies. More recently, additional indications for one-way speaking valves have been explored, including improving ventilation, weaning, and reducing aspiration; however, safety and adverse events have not been well defined. Objectives: The aim of this study was to examine the cardiorespiratory changes that occur with prolonged use of a one-way speaking valve in relation to safety and efficacy. Methods: A prospective observational study of adult patients (n = 20) was carried out in a tertiary level intensive care unit. Continuous monitoring of cardiorespiratory parameters, including heart rate (beats per minutes), respiratory rate (breaths per minute), systolic, diastolic, and mean arterial pressure (mmHg), and oxygen saturations (%), was conducted for 2 h whilst participants used a one-way speaking valve. The participants then continued to use the one-way speaking valve as long as tolerated. Data are reported as median and range (non-normative data) or as mean ± standard deviation (normative data). Results: The time to tracheostomy was 17.5 (range = 7–54) days after the initiation of mechanical ventilation, and the time to first use of the one-way speaking valve was 11.4 days (standard deviation = 5.46) after tracheostomy. The participants tolerated using a one-way speaking valve (for more than 2 h) after a median of 2 (range = 1–8) days from first use. There were no significant changes to any cardiorespiratory parameters over the 2-h period and also no adverse events in this study whilst participants used one-way speaking valves for up to 17 (range = 5.5–17) hours. Conclusions: The prolonged use of a one-way speaking valve is safe for patients who reached a threshold of 2 h.
    View less >
    Journal Title
    Australian Critical Care
    DOI
    https://doi.org/10.1016/j.aucc.2020.09.003
    Note
    This publication has been entered into Griffith Research Online as an Advanced Online Version.
    Subject
    Clinical sciences
    Nursing
    Publication URI
    http://hdl.handle.net/10072/399523
    Collection
    • Journal articles

    Footer

    Disclaimer

    • Privacy policy
    • Copyright matters
    • CRICOS Provider - 00233E
    • TEQSA: PRV12076

    Tagline

    • Gold Coast
    • Logan
    • Brisbane - Queensland, Australia
    First Peoples of Australia
    • Aboriginal
    • Torres Strait Islander