A pilot study comparing two burn wound stereophotogrammetry systems in a paediatric population
Author(s)
Bairagi, Anjana
Frear, Cody
Sweeting, Caitlin
Kimble, Roy
Griffin, Bronwyn
Griffith University Author(s)
Year published
2021
Metadata
Show full item recordAbstract
BACKGROUND: Stereophotogrammetry (SPG) provides a more objective measurement of burn wound area than traditional clinical assessments. The recently developed Intel® RealSense™ D415/Wound Measure SPG system has yet to undergo formal evaluation in a paediatric population. METHODS: A pilot study comparing the Intel® RealSense™ D415/Wound Measure to the previously validated LifeVizII®/DermaPix® SPG system, for burn assessment was conducted at a tertiary paediatric burn centre. Both systems were used to photograph and analyse the same acute wounds for each patient. Three independent raters measured wound area and perimeter. Level ...
View more >BACKGROUND: Stereophotogrammetry (SPG) provides a more objective measurement of burn wound area than traditional clinical assessments. The recently developed Intel® RealSense™ D415/Wound Measure SPG system has yet to undergo formal evaluation in a paediatric population. METHODS: A pilot study comparing the Intel® RealSense™ D415/Wound Measure to the previously validated LifeVizII®/DermaPix® SPG system, for burn assessment was conducted at a tertiary paediatric burn centre. Both systems were used to photograph and analyse the same acute wounds for each patient. Three independent raters measured wound area and perimeter. Level of agreement between systems and raters was estimated by calculating the intra-class correlation coefficient. RESULTS: Wound area measurements were completed in both systems for 25 burns from 13 patients (median age, 2 years). The participants were mainly female (n = 9), with a median TBSA-B of 9% (IQR 3-20%). There was strong agreement between the systems 0.757 (95% CI 0.521, 0.885, p < 0.001). Within each SPG system, there was excellent inter-rater reliability. CONCLUSION: The Intel® RealSense™ D415/Wound Measure system may be a viable addition to the clinician's toolkit in the assessment of paediatric burn wound area. As with other SPG systems, there were significant challenges measuring wounds to highly contoured surfaces.
View less >
View more >BACKGROUND: Stereophotogrammetry (SPG) provides a more objective measurement of burn wound area than traditional clinical assessments. The recently developed Intel® RealSense™ D415/Wound Measure SPG system has yet to undergo formal evaluation in a paediatric population. METHODS: A pilot study comparing the Intel® RealSense™ D415/Wound Measure to the previously validated LifeVizII®/DermaPix® SPG system, for burn assessment was conducted at a tertiary paediatric burn centre. Both systems were used to photograph and analyse the same acute wounds for each patient. Three independent raters measured wound area and perimeter. Level of agreement between systems and raters was estimated by calculating the intra-class correlation coefficient. RESULTS: Wound area measurements were completed in both systems for 25 burns from 13 patients (median age, 2 years). The participants were mainly female (n = 9), with a median TBSA-B of 9% (IQR 3-20%). There was strong agreement between the systems 0.757 (95% CI 0.521, 0.885, p < 0.001). Within each SPG system, there was excellent inter-rater reliability. CONCLUSION: The Intel® RealSense™ D415/Wound Measure system may be a viable addition to the clinician's toolkit in the assessment of paediatric burn wound area. As with other SPG systems, there were significant challenges measuring wounds to highly contoured surfaces.
View less >
Journal Title
Burns
Note
This publication has been entered in Griffith Research Online as an advanced online version.
Subject
Paediatrics
Reproductive medicine
Clinical sciences
3D camera
Burn size measurement
Burn wound
Child
Stereophotogrammetry