dc.description.abstract | Highly cross-linked polyethylene was developed to reduce articular bearing wear in total hip arthroplasty. In vitro studies have shown reduced wear in comparison with conventional polyethylene. A double-blind, prospective, randomized trial was performed comparing highly cross-linked and conventional polyethylene in 119 patients. The primary outcome variables were linear, 3-dimensional, and volumetric wear as determined by analysis of digitized radiographs using validated wear measurement software. Linear, 3-dimensional, and volumetric wear rates were significantly less in the highly cross-linked polyethylene group between 6 months and 4 years postoperatively (P < .05). The data presented here show that highly cross-linked polyethylene reduces short-term polyethylene wear. The intermediate and long-term clinical results of highly cross-linked polyethylene remain unknown pending further follow-up. | |
dc.description.peerreviewed | Yes | |
dc.description.publicationstatus | Yes | |
dc.language | English | |
dc.language.iso | eng | |
dc.publisher | Elsevier | |
dc.publisher.place | United States | |
dc.relation.ispartofstudentpublication | N | |
dc.relation.ispartofpagefrom | 505 | |
dc.relation.ispartofpageto | 510 | |
dc.relation.ispartofissue | 4 | |
dc.relation.ispartofjournal | Journal of Arthroplasty | |
dc.relation.ispartofvolume | 24 | |
dc.rights.retention | Y | |
dc.subject.fieldofresearch | Medical and Health Sciences not elsewhere classified | |
dc.subject.fieldofresearch | Biomedical Engineering | |
dc.subject.fieldofresearch | Clinical Sciences | |
dc.subject.fieldofresearchcode | 119999 | |
dc.subject.fieldofresearchcode | 0903 | |
dc.subject.fieldofresearchcode | 1103 | |
dc.title | A Double-Blind, Prospective, Randomized Controlled Trial Comparing Highly Cross-Linked and Conventional Polyethylene in Primary Total Hip Arthroplasty | |
dc.type | Journal article | |
dc.type.description | C1 - Articles | |
dc.type.code | C - Journal Articles | |
gro.date.issued | 2009 | |
gro.hasfulltext | No Full Text | |
gro.griffith.author | Fielden, Jann | |