High-throughput assay for quantification of the plasma concentrations of thiopental using automated solid phase extraction (SPE) directly coupled to LC–MS/MS instrumentation
Author(s)
Moosavi, SM
Shekar, K
Fraser, J
Smith, MT
Ghassabian, S
Griffith University Author(s)
Year published
2016
Metadata
Show full item recordAbstract
Most previous assays for thiopental are time-consuming due to laborious sample extraction steps prior to analysis using gas chromatography or high pressure liquid chromatography. Here, we describe the first high-throughput liquid chromatography – tandem mass spectrometry (LC–MS/MS) method for quantification of thiopental concentrations in samples of human plasma. Robotic on-line solid phase extraction (SPE) was used to elute the analytes of interest from samples of human plasma (50 μL) loaded onto C18 SPE cartridges to which were added aliquots (50 μL) of internal standard solution (thiopental-d5 100 ng/mL) and 0.5% formic ...
View more >Most previous assays for thiopental are time-consuming due to laborious sample extraction steps prior to analysis using gas chromatography or high pressure liquid chromatography. Here, we describe the first high-throughput liquid chromatography – tandem mass spectrometry (LC–MS/MS) method for quantification of thiopental concentrations in samples of human plasma. Robotic on-line solid phase extraction (SPE) was used to elute the analytes of interest from samples of human plasma (50 μL) loaded onto C18 SPE cartridges to which were added aliquots (50 μL) of internal standard solution (thiopental-d5 100 ng/mL) and 0.5% formic acid in water (100 μL). Cartridges were washed using 10% methanol in ammonium acetate buffer (50 mM, pH 7) before elution with mobile phase comprising 0.1% formic acid in water and acetonitrile with a flow rate of 0.55 mL/min using a 7.2 min run time. The analytes were separated on a C18 XTerra® analytical column. Mass spectrometry detection was performed using a QTrap 5500 mass spectrometer (AB Sciex) with negative ionisation. The multiple reaction monitoring (MRM) transitions for thiopental and the internal standard were 241 → 58, and 246 → 58, respectively. The calibration curve was linear over a range of 6–600 ng/mL. Thiopental was stable in human plasma samples for at least 36 h in the autosampler, as well as after three cycles of freeze and thaw, and after 3 h storage at room temperature. The absolute recovery and matrix effect were 102% and 6.9%, respectively, and the within-run and between-run precision and accuracy were ≤15%. Our method is fully-validated and satisfies the requirements of the 2012 European Medicines Agency (EMEA) guideline for Bioanalytical Method Validation.
View less >
View more >Most previous assays for thiopental are time-consuming due to laborious sample extraction steps prior to analysis using gas chromatography or high pressure liquid chromatography. Here, we describe the first high-throughput liquid chromatography – tandem mass spectrometry (LC–MS/MS) method for quantification of thiopental concentrations in samples of human plasma. Robotic on-line solid phase extraction (SPE) was used to elute the analytes of interest from samples of human plasma (50 μL) loaded onto C18 SPE cartridges to which were added aliquots (50 μL) of internal standard solution (thiopental-d5 100 ng/mL) and 0.5% formic acid in water (100 μL). Cartridges were washed using 10% methanol in ammonium acetate buffer (50 mM, pH 7) before elution with mobile phase comprising 0.1% formic acid in water and acetonitrile with a flow rate of 0.55 mL/min using a 7.2 min run time. The analytes were separated on a C18 XTerra® analytical column. Mass spectrometry detection was performed using a QTrap 5500 mass spectrometer (AB Sciex) with negative ionisation. The multiple reaction monitoring (MRM) transitions for thiopental and the internal standard were 241 → 58, and 246 → 58, respectively. The calibration curve was linear over a range of 6–600 ng/mL. Thiopental was stable in human plasma samples for at least 36 h in the autosampler, as well as after three cycles of freeze and thaw, and after 3 h storage at room temperature. The absolute recovery and matrix effect were 102% and 6.9%, respectively, and the within-run and between-run precision and accuracy were ≤15%. Our method is fully-validated and satisfies the requirements of the 2012 European Medicines Agency (EMEA) guideline for Bioanalytical Method Validation.
View less >
Journal Title
Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences
Volume
1038
Subject
Analytical chemistry
Biochemistry and cell biology
Pharmacology and pharmaceutical sciences
Bioanalysis
LC–MS/MS
Method development
Solid phase extraction
Thiopental