Show simple item record

dc.contributor.authorSoda, N
dc.contributor.authorArotiba, OA
dc.date.accessioned2021-11-05T04:41:07Z
dc.date.available2021-11-05T04:41:07Z
dc.date.issued2017
dc.identifier.issn1452-3981
dc.identifier.doi10.20964/2017.11.10
dc.identifier.urihttp://hdl.handle.net/10072/409873
dc.description.abstractThis work reports the development of an electrochemical aptasensor for thrombin based on a polyamidoamine dendrimer-streptavidin supramolecular architecture prepared by the cyclic voltammetric electrodeposition of polyamidoamine dendrimer (PAMAM) followed by the drop coating of streptavidin on a glassy carbon electrode. Biotinylated aptamer probe was immobilised on the platform through biotin-streptavidin interaction. The aptasensor preparation was monitored with voltammetry and electrochemical impedance spectroscopy. The biosensor response to thrombin was evaluated with square wave voltammetry (in phosphate buffer solution and in ferro/ferric cyanide probe) and electrochemical impedance spectroscopy. Linear responses in the concentration range between 1 - 200 ng mL-1 and detection limit in the sub 0.02 ng mL-1 (defined as ( ) were calculated. The selectivity of the aptasensor was evaluated using interfering proteins such as bovine serum albumin (BSA), lysozyme and haemoglobin. The relative response obtained shows insignificant effect from the interfering proteins with BSA, lysozyme and haemoglobin having a relative response of 9.2%, 8.7% and 7.6% respectively.
dc.description.peerreviewedYes
dc.languageEnglish
dc.publisherESG
dc.relation.ispartofpagefrom10359
dc.relation.ispartofpageto10368
dc.relation.ispartofissue11
dc.relation.ispartofjournalInternational Journal of Electrochemical Science
dc.relation.ispartofvolume12
dc.subject.fieldofresearchAnalytical chemistry
dc.subject.fieldofresearchPhysical chemistry
dc.subject.fieldofresearchcode3401
dc.subject.fieldofresearchcode3406
dc.subject.keywordsScience & Technology
dc.subject.keywordsPhysical Sciences
dc.subject.keywordsElectrochemistry
dc.subject.keywordsBiosensor
dc.subject.keywordsthrombin
dc.titleAn electrochemical aptasensor for thrombin based on a novel polyamidoamine dendrimer-streptavidin supramolecular architecture
dc.typeJournal article
dc.type.descriptionC1 - Articles
dcterms.bibliographicCitationSoda, N; Arotiba, OA, An electrochemical aptasensor for thrombin based on a novel polyamidoamine dendrimer-streptavidin supramolecular architecture, International Journal of Electrochemical Science, 2017, 12 (11), pp. 10359-10368
dc.date.updated2021-11-05T04:36:44Z
gro.hasfulltextNo Full Text
gro.griffith.authorSoda, Narshone


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

  • Journal articles
    Contains articles published by Griffith authors in scholarly journals.

Show simple item record