• myGriffith
    • Staff portal
    • Contact Us⌄
      • Future student enquiries 1800 677 728
      • Current student enquiries 1800 154 055
      • International enquiries +61 7 3735 6425
      • General enquiries 07 3735 7111
      • Online enquiries
      • Staff phonebook
    View Item 
    •   Home
    • Griffith Theses
    • Theses - Higher Degree by Research
    • View Item
    • Home
    • Griffith Theses
    • Theses - Higher Degree by Research
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Browse

  • All of Griffith Research Online
    • Communities & Collections
    • Authors
    • By Issue Date
    • Titles
  • This Collection
    • Authors
    • By Issue Date
    • Titles
  • Statistics

  • Most Popular Items
  • Statistics by Country
  • Most Popular Authors
  • Support

  • Contact us
  • FAQs
  • Admin login

  • Login
  • Development of a novel sutureless inflow cannula for ventricular assist device implantation

    Thumbnail
    View/Open
    Embargoed until: 2024-01-10
    Author(s)
    Garrick, Kristy M
    Primary Supervisor
    Hall, Wayne
    Other Supervisors
    Tansley, Geoffrey
    Gregory, Shaun D
    Bartnikowski, Nicole
    Year published
    2023-01-10
    Metadata
    Show full item record
    Abstract
    Heart failure affects an estimated 26 million people worldwide, and at any one time 300,000 Australians. Whilst the gold standard treatment for heart failure is heart transplantation, a shortage of donor hearts limits the availability of this lifesaving intervention. Mechanical circulatory support devices offer a promising alternative treatment for not only patients on the transplantation waiting list, but also as a destination therapy for patients who are not eligible for transplantation. Ventricular assist devices (VADs) are a form of mechanical circulatory support used to support the function of the failing heart when the ...
    View more >
    Heart failure affects an estimated 26 million people worldwide, and at any one time 300,000 Australians. Whilst the gold standard treatment for heart failure is heart transplantation, a shortage of donor hearts limits the availability of this lifesaving intervention. Mechanical circulatory support devices offer a promising alternative treatment for not only patients on the transplantation waiting list, but also as a destination therapy for patients who are not eligible for transplantation. Ventricular assist devices (VADs) are a form of mechanical circulatory support used to support the function of the failing heart when the heart is unable to maintain adequate cardiac output. Most commonly a VAD will work in parallel with the native left ventricle (LV), with inflow cannula implantation performed through the apex of the LV and secured to the epicardium with a suture ring. Common complications of VAD implantation and support, such as surgical bleeding, can be attributed in part to inflow cannula design or placement. Extended time on cardiopulmonary bypass (utilised during VAD implantation) is also associated with inferior postoperative outcomes. To address the complications influenced by extended surgical time, and inflow cannula design and placement, Shaun Gregory developed a novel sutureless cannula through his doctoral research. The cannula was introduced in a chapter of his thesis and awarded a provisional patent (now lapsed). Gregory’s research involved the design and manufacture of a proof-of-concept device, and its implantation within cadaveric hearts connected to an ex-vivo mock circulation loop that evaluated the ability of the device to provide a blood-tight seal through the compression of the myocardium between the internal and external components. In 2016 a paper was published that evaluated different inflow cannula tip geometries for thrombus risk within an in-silico heart model, from the same research group. One of the five cannulae modelled had an inferiorly flared internal geometry, indicative of Gregory’s cannula, however it was only a representative model with an idealised internal geometric shape. Beyond this publication there has been no further research, device development, or device evaluation undertaken or published involving the sutureless inflow cannulae (SLIC) until this doctoral research. The doctoral research presented within this thesis aimed to continue the development beyond proof-of-concept and undertake a critical evaluation of the SLIC. To undertake further evaluation of the SLIC a critical review of the cannula developed by Gregory was undertaken, where the limitations of the design were addressed, and the device progressed through design changes. For development of an implantable medical device one of the evaluations conducted is implantation within an animal in the acute setting. To continue with its evaluation the SLIC was implanted in-vivo (within pigs) through an acute study and evaluated against parameters such as the ability of the SLIC to be implanted in under 2 minutes, for the SLIC to provide a secure haemostatic seal across the myocardial wall, and there to be no bleeding at the site of SLIC implantation. To investigate the impact the compressive seal of the SLIC had on the myocardium, histology review was conducted on sectioned cardiac tissue from all five animals against markers for myocardial injury. Whilst the initial two animals in the acute in-vivo study had successful outcomes across all areas evaluated, the following three animals all suffered adverse events due to internal cardiac geometry incompatible with SLIC implantation (hypertrophic cardiomyopathy), or surgical error (near-complete oversew of the outflow graft). The final animal implanted with the SLIC had undiagnosed severe hypertrophic cardiomyopathy that resulted, during attempted implantation, in critical breakage of the SLIC within the LV. Histological review against immunohistochemical markers for early onset myocardial injury also produced positive results, primarily seen at the site of implantation through expression of Tumor Necrosis Factor Alpha, and depletion of Cardiac Troponin T and Myoglobin. Haematoxylin and Eosin staining also revealed changers indicative of early onset damage such as wavy fibres, interstitial oedema, granulation formation, and hypereosinophilia of some cardiomyocytes. These results, in combination with the in-vitro testing determining forces applied by the SLIC onto the cardiac tissue, provide indication that the current implantation securement mechanism of the SLIC causes myocardial injury. The final research conducted and described in this doctoral thesis details the redesign process of the SLIC, that extracts the outcomes from the research and formulates new device development inputs. A proof-of-concept device is introduced in the final research chapter. The main finding of this doctoral research indicates that a SLIC that is capable of rapid implantation, without the reliance on suturing into place for secure fixation is feasible and capable of working in conjunction with a VAD to support cardiac function. However, the impact that the compressive locking mechanism has on the tissue it is implanted within requires attention and consideration in any future work design parameters to ensure development of an implantable medical device suitable for long-term implantation.
    View less >
    Thesis Type
    Thesis (PhD Doctorate)
    Degree Program
    Doctor of Philosophy (PhD)
    School
    School of Eng & Built Env
    Copyright Statement
    The author owns the copyright in this thesis, unless stated otherwise.
    Subject
    heart failure
    ventricular assist device
    inflow cannula
    sutureless cannula fixation
    immunohistochemistry
    in-vivo study
    Publication URI
    http://hdl.handle.net/10072/421122
    Collection
    • Theses - Higher Degree by Research

    Footer

    Disclaimer

    • Privacy policy
    • Copyright matters
    • CRICOS Provider - 00233E
    • TEQSA: PRV12076

    Tagline

    • Gold Coast
    • Logan
    • Brisbane - Queensland, Australia
    First Peoples of Australia
    • Aboriginal
    • Torres Strait Islander