dc.description.abstractA convenient, robust, economical and selective sample preparation method for the quantitative determination of entecavir in human plasma by LC-MS was developed and validated. Entecavir and the internal standard of acyclovir were extracted from 500 匠of human plasma by a salting-out homogeneous liquid-liquid extraction approach (SHLLE) with acetonitrile as the organic extractant and magnesium sulfate as the salting-out reagent. They were analyzed on a Hanbonichrospher RP C18 HPLC column (150 mm נ2.0 mm; 5 孩 with gradient elution. The mobile phase comprised 0.1% acetic acid-0.2 mmol ammonium acetate in water (mobile phase A) and acetonitrile (mobile phase B). The flow rate is 0.2 mL/min. The analytes were detected by a LC-MS 2010 single quadrupole mass spectrometer instrument equipped with an electrospray ionization interface using selective ion monitoring positive mode. A "post cut" column switch technique was incorporated into the method to remove interferences of earlier and later eluting matrix components than entecavir and internal standard, including salting-out reagent used in sample pre-processing. The method was validated over the concentration range of 0.05-20 ng/mL. The intra-day and inter-day precision of the assay, as measured by the coefficient of variation (%CV), was within 3.59%, and the intra-day assay accuracy was found to be within 4.88%. The average recovery of entecavir was about 50% and the ion suppression was approximately 44% over the standard curve. Comparison of matrix effect between SHLLE and SPE by continuous post column infusion showed that these two methods got similar, slight ion suppression. The SHLLE method has been successfully utilized for the analysis of entecavir in post-dose samples from a clinical study.
dc.description.peerreviewedYes
dc.description.publicationstatusYes
dc.languageEnglish
dc.language.isoeng
dc.publisherElsevier
dc.publisher.placeNetherlands
dc.relation.ispartofstudentpublicationN
dc.relation.ispartofpagefrom119
dc.relation.ispartofpageto125
dc.relation.ispartofjournalJournal of Chromatography B
dc.relation.ispartofvolume881-882
dc.rights.retentionY
dc.subject.fieldofresearchAnalytical chemistry
dc.subject.fieldofresearchBiochemistry and cell biology
dc.subject.fieldofresearchPharmacology and pharmaceutical sciences
dc.subject.fieldofresearchPharmacology and pharmaceutical sciences not elsewhere classified
dc.subject.fieldofresearchcode3401
dc.subject.fieldofresearchcode3101
dc.subject.fieldofresearchcode3214
dc.subject.fieldofresearchcode321499
dc.titleSalting-out homogeneous liquid–liquid extraction approach applied in sample pre-processing for the quantitative determination of entecavir in human plasma by LC–MS
dc.typeJournal article
dc.type.descriptionC1 - Articles
dc.type.codeC - Journal Articles
gro.date.issued2012
gro.hasfulltextNo Full Text
gro.griffith.authorDavey, Andrew


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

  • Journal articles
    Contains articles published by Griffith authors in scholarly journals.

Show simple item record