Show simple item record

dc.contributor.authorAli, MS
dc.contributor.authorPota, HR
dc.contributor.authorMahmud, MA
dc.contributor.authorHossain, MJ
dc.contributor.editorProf. Arindum Ghosh
dc.date.accessioned2017-05-03T16:07:20Z
dc.date.available2017-05-03T16:07:20Z
dc.date.issued2011
dc.date.modified2013-01-03T23:44:28Z
dc.identifier.isbn9781457717932
dc.identifier.urihttp://hdl.handle.net/10072/48835
dc.description.abstractIn this paper, the modelling of distribution network with Doubly Fed Induction Generator (DFIG) is presented in a different way where the resistances of the lines are considered. Induction motor is considered as dynamic load which causes the voltage stability problems in power distribution system. Based on this modelling, this paper presents an analysis to investigate the critical parameters for distribution systems with dynamic loads where DFIGs are used as distributed generation that affect the stability. In order to analyze the critical parameters, the system is linearized about an operating point by using Taylor series expansion method. The critical parameters are investigated through the concept of eigenvalues and participation factors. Finally this paper shows that varying the line resistor, the marginally stable system goes to the unstable mode.
dc.description.peerreviewedYes
dc.description.publicationstatusYes
dc.languageEnglish
dc.publisherAustralasian Universities Power Engineering Conference
dc.publisher.placeBrisbane, Australia
dc.publisher.urihttp://aupec2012.org/?page_id=13
dc.relation.ispartofstudentpublicationN
dc.relation.ispartofconferencenameAustralasian Universities Power Engineering Conference (AUPEC)
dc.relation.ispartofconferencetitle2011 AUSTRALASIAN UNIVERSITIES POWER ENGINEERING CONFERENCE (AUPEC)
dc.relation.ispartofdatefrom2011-09-25
dc.relation.ispartofdateto2011-09-28
dc.relation.ispartoflocationBrisbane, AUSTRALIA
dc.rights.retentionY
dc.subject.fieldofresearchElectrical energy generation (incl. renewables, excl. photovoltaics)
dc.subject.fieldofresearchcode400803
dc.titleIdentification of Critical Parameters for Distribution Networks with DFIG and Dynamic loads
dc.typeConference output
dc.type.descriptionE1 - Conferences
dc.type.codeE - Conference Publications
gro.date.issued2012
gro.hasfulltextNo Full Text
gro.griffith.authorHossain, Jahangir


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

  • Conference outputs
    Contains papers delivered by Griffith authors at national and international conferences.

Show simple item record