• myGriffith
    • Staff portal
    • Contact Us⌄
      • Future student enquiries 1800 677 728
      • Current student enquiries 1800 154 055
      • International enquiries +61 7 3735 6425
      • General enquiries 07 3735 7111
      • Online enquiries
      • Staff phonebook
    View Item 
    •   Home
    • Griffith Research Online
    • Journal articles
    • View Item
    • Home
    • Griffith Research Online
    • Journal articles
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Browse

  • All of Griffith Research Online
    • Communities & Collections
    • Authors
    • By Issue Date
    • Titles
  • This Collection
    • Authors
    • By Issue Date
    • Titles
  • Statistics

  • Most Popular Items
  • Statistics by Country
  • Most Popular Authors
  • Support

  • Contact us
  • FAQs
  • Admin login

  • Login
  • VAR Planning With Tuning of STATCOM in a DG Integrated Industrial System

    Author(s)
    Aziz, T
    Hossain, MJ
    Saha, TK
    Mithulananthan, N
    Griffith University Author(s)
    Hossain, Jahangir
    Year published
    2013
    Metadata
    Show full item record
    Abstract
    Wide-scale penetration of distributed-generation (DG) units into a weakly meshed distribution system is one of the major concerns for power system engineers in recent years. As grid standards limit voltage control operation of small DG units, a lack of sufficient reactive power support brings the problem of slow voltage recovery and this leads to the usage of expensive flexible ac transmission system (FACTS) devices, such as a static synchronous compensator (STATCOM). In this paper, a systematic methodology has been developed for fast voltage recovery at the DG bus. This methodology reduces the number as well as the rating ...
    View more >
    Wide-scale penetration of distributed-generation (DG) units into a weakly meshed distribution system is one of the major concerns for power system engineers in recent years. As grid standards limit voltage control operation of small DG units, a lack of sufficient reactive power support brings the problem of slow voltage recovery and this leads to the usage of expensive flexible ac transmission system (FACTS) devices, such as a static synchronous compensator (STATCOM). In this paper, a systematic methodology has been developed for fast voltage recovery at the DG bus. This methodology reduces the number as well as the rating of STATCOMs through the tuning of control parameters. The STATCOM rating at selected locations has been tested and verified to be adequate at various dispatch levels of DG units. Additional benefits of STATCOM tuning on the damping of weak modes have also been studied. An IEEE industrial test system has been used for validating the methodology, providing grid compatible voltage recovery and satisfactory damping performance.
    View less >
    Journal Title
    IEEE Transactions on Power Delivery
    Volume
    28
    Issue
    2
    DOI
    https://doi.org/10.1109/TPWRD.2012.2229722
    Subject
    Electrical energy generation (incl. renewables, excl. photovoltaics)
    Publication URI