dc.contributor.authorCaruana, LR
dc.contributor.authorParatz, J
dc.contributor.authorChang, AT
dc.contributor.authorFraser, JF
dc.date.accessioned2017-05-16T12:31:05Z
dc.date.available2017-05-16T12:31:05Z
dc.date.issued2011
dc.date.modified2014-07-22T04:31:01Z
dc.identifier.issn1083-3196
dc.identifier.doi10.1179/1743288X10Y.0000000021
dc.identifier.urihttp://hdl.handle.net/10072/61582
dc.description.abstractBackground: Mechanical ventilation has dramatically improved outcomes in critically ill patients with respiratory failure. Minimizing volumes and higher positive end-expiratory pressures can further improve patient outcomes. Recruitment manoeuvres which can be used to individualize positive end-expiratory pressure may not improve outcome unless recruitable tissue is present. Existing methods of assessing if lung tissue is recruitable have a variety of limitations. Electrical impedance tomography (EIT) is a new technology that may be able to assess whether or not lung tissue is recruitable at the bedside. Objectives: This review will assess the growing body of evidence that EIT is a promising technique which may help the clinician to optimize ventilation, while minimizing injury. We will review how the device works, the data supporting its use, and potential uses for the physical therapist in the critical care environment. Major findings: EIT is a technique of injecting current through tissue, and measuring the difference between an array of electrodes. The difference relates to the changes of volume within the chest cavity - either blood or gas. It is reproducible, non-radiative, and real-time - allowing immediate and repeated imaging in the sickest of patients, who may require high levels of peep and recruitment manoeuvres. Conclusions: This paper has demonstrated that with an understanding of the strengths and limitations of the device, EIT can be used successfully at the bedside by clinicians to guide recruitment and other clinical techniques.
dc.description.peerreviewedYes
dc.description.publicationstatusYes
dc.languageEnglish
dc.language.isoeng
dc.publisherManey Publishing
dc.publisher.placeUnited Kingdom
dc.relation.ispartofstudentpublicationN
dc.relation.ispartofpagefrom66
dc.relation.ispartofpageto74
dc.relation.ispartofissue1
dc.relation.ispartofjournalPhysical therapy reviews
dc.relation.ispartofvolume16
dc.rights.retentionY
dc.subject.fieldofresearchClinical Sciences not elsewhere classified
dc.subject.fieldofresearchClinical Sciences
dc.subject.fieldofresearchHuman Movement and Sports Sciences
dc.subject.fieldofresearchcode110399
dc.subject.fieldofresearchcode1103
dc.subject.fieldofresearchcode1106
dc.titleElectrical impedance tomography in the clinical assessment of lung volumes following recruitment manoeuvres
dc.typeJournal article
dc.type.descriptionC1 - Articles
dc.type.codeC - Journal Articles
gro.hasfulltextNo Full Text
gro.griffith.authorParatz, Jenny D.
gro.griffith.authorFraser, John F.


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

  • Journal articles
    Contains articles published by Griffith authors in scholarly journals.

Show simple item record