Show simple item record

dc.contributor.authorLuis, Sushil A
dc.contributor.authorYamada, Akira
dc.contributor.authorKhandheria, Bijoy K
dc.contributor.authorSperanza, Vicki
dc.contributor.authorBenjamin, Anthony
dc.contributor.authorIschenko, Matthew
dc.contributor.authorPlatts, David G
dc.contributor.authorHamilton-Craig, Christian R
dc.contributor.authorHaseler, Luke
dc.contributor.authorBurstow, Darryl
dc.contributor.authorChan, Jonathan
dc.date.accessioned2017-05-03T15:01:35Z
dc.date.available2017-05-03T15:01:35Z
dc.date.issued2014
dc.date.modified2014-08-05T23:02:40Z
dc.identifier.issn0894-7317
dc.identifier.doi10.1016/j.echo.2013.11.002
dc.identifier.urihttp://hdl.handle.net/10072/61885
dc.description.abstractAbstract BACKGROUND: The aim of this study was to determine whether global strains derived from three-dimensional (3D) speckle-tracking echocardiography (STE) are as accurate as left ventricular (LV) ejection fraction (LVEF) obtained by two-dimensional (2D) and 3D echocardiography in the quantification of LV function. METHODS: Two-dimensional and 3D echocardiography and 2D and 3D STE were performed in 88 patients (LVEF range, 17%-79%). Two-dimensional and 3D global longitudinal strain (GLS), global circumferential strain (GCS), global radial strain, and global area strain were quantified and correlated with LV function determined by 2D and 3D echocardiographic LVEF. Reproducibility, feasibility, and duration of study to perform 3D STE were assessed by independent, blinded observers. RESULTS: A total of 78 patients (89%) underwent 3D STE. All 3D speckle-tracking echocardiographic parameters had strong correlations with assessment of LV function determined by 2D and 3D echocardiographic LVEF. Three-dimensional GCS was the best marker of LV function (r = -0.89, P < .0001). Subgroup analysis demonstrated that 3D speckle-tracking echocardiographic parameters were particularly useful in identifying LV dysfunction (LVEF < 50%). Receiver operating characteristic curve analysis demonstrated areas under the curve of 0.97 for 3D GCS, 0.96 for 3D global radial strain, 0.95 for 3D global area strain, and 0.87 for 3D GLS. An optimal 3D GCS cutoff value of magnitude < -12% predicted LV dysfunction (LVEF obtained by 2D echocardiography < 50%) with 92% sensitivity and 90% specificity. There was good correlation between 2D GLS and 3D GLS (r = 0.85, P < .001; mean difference, -1.7 ᠶ.5%). Good intraobserver, interobserver, and test-retest agreements were seen with 3D STE. Time for image acquisition to postprocessing analysis was significantly reduced with 3D STE (3.7 ᠱ.0 minutes) compared with 2D STE (4.6 ᠱ.5 min) (P < .05). CONCLUSIONS: Global strain by 3D STE is a promising novel alternative to quantitatively assess LV function. Three-dimensional STE is reproducible, feasible, and time efficient.
dc.description.peerreviewedYes
dc.description.publicationstatusYes
dc.languageEnglish
dc.language.isoeng
dc.publisherMosby
dc.publisher.placeUnited States
dc.relation.ispartofstudentpublicationN
dc.relation.ispartofpagefrom285
dc.relation.ispartofpageto291
dc.relation.ispartofissue3
dc.relation.ispartofjournalJournal of the American Society of Echocardiography
dc.relation.ispartofvolume27
dc.rights.retentionY
dc.subject.fieldofresearchCardiovascular medicine and haematology
dc.subject.fieldofresearchCardiology (incl. cardiovascular diseases)
dc.subject.fieldofresearchcode3201
dc.subject.fieldofresearchcode320101
dc.titleUse of Three-Dimensional Speckle-Tracking Echocardiography for Quantitative Assessment of Global Left Ventricular Function: A Comparative Study to Three-Dimensional Echocardiography
dc.typeJournal article
dc.type.descriptionC1 - Articles
dc.type.codeC - Journal Articles
gro.hasfulltextNo Full Text
gro.griffith.authorChan, Jonathan H.


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

  • Journal articles
    Contains articles published by Griffith authors in scholarly journals.

Show simple item record