Active gap reduction in comb drive of three axes capacitive micro accelerometer for enhancing sense capacitance and sensitivity
Author(s)
Riaz, Kashif
Iqbal, Abid
Umer Mian, M.
Bazaz, Shafaat
Griffith University Author(s)
Year published
2014
Metadata
Show full item recordAbstract
The performance of micro-machined sensors is primarily determined via the sensitivity of sensing electrode to displacement. This paper presents the design, modelling, optimization and fabrication of an active gap reduction mechanism used on a conventional comb drive to enhance the capacitance in a three axes capacitive micro accelerometer. The design parameters of the active gap reduced comb drive (AGRCD) are optimized for best performance. The finite element analysis of the AGRCD is performed for design verification. The modeling and simulation results demonstrated a 534 % increase in sensitivity of the three axes capacitive ...
View more >The performance of micro-machined sensors is primarily determined via the sensitivity of sensing electrode to displacement. This paper presents the design, modelling, optimization and fabrication of an active gap reduction mechanism used on a conventional comb drive to enhance the capacitance in a three axes capacitive micro accelerometer. The design parameters of the active gap reduced comb drive (AGRCD) are optimized for best performance. The finite element analysis of the AGRCD is performed for design verification. The modeling and simulation results demonstrated a 534 % increase in sensitivity of the three axes capacitive micro accelerometer. The three axes capacitive micro accelerometer with AGRCD is fabricated using a commercially available standard metal-multi user MEMS processes.
View less >
View more >The performance of micro-machined sensors is primarily determined via the sensitivity of sensing electrode to displacement. This paper presents the design, modelling, optimization and fabrication of an active gap reduction mechanism used on a conventional comb drive to enhance the capacitance in a three axes capacitive micro accelerometer. The design parameters of the active gap reduced comb drive (AGRCD) are optimized for best performance. The finite element analysis of the AGRCD is performed for design verification. The modeling and simulation results demonstrated a 534 % increase in sensitivity of the three axes capacitive micro accelerometer. The three axes capacitive micro accelerometer with AGRCD is fabricated using a commercially available standard metal-multi user MEMS processes.
View less >
Journal Title
Microsystem Technologies
Subject
Communications Technologies not elsewhere classified
Nanotechnology not elsewhere classified
Communications Technologies
Nanotechnology