Knee Compliance Reduces Peak Swing Phase Collision Forces in a Lower-Limb Exoskeleton Leg: A Test Bench Evaluation

Loading...
Thumbnail Image
File version

Accepted Manuscript (AM)

Author(s)
Schrade, Stefan O
Menner, Marcel
Shirota, Camila
Winiger, Peter
Stutz, Alex
Zeilinger, Melanie N
Lambercy, Olivier
Gassert, Roger
Griffith University Author(s)
Primary Supervisor
Other Supervisors
Editor(s)
Date
2021
Size
File type(s)
Location
License
Abstract

Powered lower limb exoskeletons are a viable solution for people with a spinal cord injury to regain mobility for their daily activities. However, the commonly employed rigid actuation and pre-programmed trajectories increase the risk of falling in case of collisions with external objects. Compliant actuation may reduce forces during collisions, thus protecting hardware and user. However, experimental data of collisions specific to lower limb exoskeletons are not available. In this work, we investigated how a variable stiffness actuator at the knee joint influences collision forces transmitted to the user via the exoskeleton. In a test bench experiment, we compared three configurations of an exoskeleton leg with a variable stiffness knee actuator in (i) compliant or (ii) stiff configurations, and with (iii) a rigid actuator. The peak torque observed at the pelvis was reduced from 260.2 Nm to 116.2 Nm as stiffness decreased. In addition, the mechanical impulse was reduced by a factor of three. These results indicate that compliance in the knee joint of an exoskeleton can be favorable in case of collision and should be considered when designing powered lower limb exoskeletons. Overall, this could decrease the effort necessary to maintain balance after a collision, and improved collision handling in exoskeletons could result in safer use and benefit their usefulness in daily life.

Journal Title

IEEE Transactions on Biomedical Engineering

Conference Title
Book Title
Edition
Volume

68

Issue

2

Thesis Type
Degree Program
School
Publisher link
Patent number
Funder(s)
Grant identifier(s)
Rights Statement
Rights Statement

© 2021 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.

Item Access Status
Note
Access the data
Related item(s)
Subject

Biomedical engineering

Science & Technology

Technology

Engineering, Biomedical

Engineering

Exoskeletons

Persistent link to this record
Citation

Schrade, SO; Menner, M; Shirota, C; Winiger, P; Stutz, A; Zeilinger, MN; Lambercy, O; Gassert, R, Knee Compliance Reduces Peak Swing Phase Collision Forces in a Lower-Limb Exoskeleton Leg: A Test Bench Evaluation, IEEE Transactions on Biomedical Engineering, 2021, 68 (2), pp. 535-544

Collections