Optimised minus lens overcorrection for paediatric intermittent exotropia: A randomised clinical trial
File version
Accepted Manuscript (AM)
Author(s)
Shah, Shaheen P
Webber, Ann
Sleep, Michael G
Dai, Shuan H
Griffith University Author(s)
Primary Supervisor
Other Supervisors
Editor(s)
Date
Size
File type(s)
Location
License
Abstract
Background Aim of this study was to evaluate the efficacy of a novel algorithm to customise overminus lens therapy in intermittent exotropia (IXT) based on clinical factors associated with control of the deviation.
Methods Clinical parameters in IXT vary among individuals. Based on individual's physiological factors, an algorithm was developed. Children aged between 4 and 15 years with IXT were randomised into OML and observation groups. Participants in the observation group were corrected for any significant refractive error. IXT control score, angle of deviation, refraction, axial length and stereopsis were examined at baseline and follow up ranging between 6 and 15 months and compared. Compliance and tolerance to OML was determined by a symptom survey.
Results The OML power ranged between −1.00D and − 6.25D. Of the total 141 participants (mean age 6.8 ± 2.5 year), 77 were in the OML and 66 were in observation group. IXT control score improved (mean difference − 2.5 ± 1.1; p < 0.001) and angle of deviation reduced (6.9 ± 7.2pd; p < 0.001) significantly in the OML group only. Compliance rate to OML wear was 80%; 90% never or rarely experienced asthenopia symptoms. Slightly greater myopic shift (−0.36 ± 0.53D vs. −0.18 ± 0.55D) and change in axial length (0.17 vs. 0.14 mm) were observed in the OML group, but these differences were not statistically significant.
Conclusions A customised OML, calculated using this novel algorithm was effective in improving distance control, angle of deviation and stereopsis. Glasses wear was highly tolerable.
Journal Title
Clinical & Experimental Ophthalmology
Conference Title
Book Title
Edition
Volume
50
Issue
4
Thesis Type
Degree Program
School
Publisher link
Patent number
Funder(s)
Grant identifier(s)
Rights Statement
Rights Statement
This work is covered by copyright. You must assume that re-use is limited to personal use and that permission from the copyright owner must be obtained for all other uses. If the document is available under a specified licence, refer to the licence for details of permitted re-use. If you believe that this work infringes copyright please make a copyright takedown request using the form at https://www.griffith.edu.au/copyright-matters.
Item Access Status
Note
Access the data
Related item(s)
Subject
Ophthalmology and optometry
Science & Technology
Life Sciences & Biomedicine
Ophthalmology
intermittent exotropia
myopic shift
Persistent link to this record
Citation
Magar, JBA; Shah, SP; Webber, A; Sleep, MG; Dai, SH, Optimised minus lens overcorrection for paediatric intermittent exotropia: A randomised clinical trial, Clinical & Experimental Ophthalmology, 2022, 50 (4), pp. 407-419