Automatic Detection of Stimulation Artifacts to Isolate Volitional from Evoked EMG Activity

Loading...
Thumbnail Image
File version

Version of Record (VoR)

Author(s)
de Sousa, Ana Carolina C
Valtin, Markus
Bó, Antônio PL
Schauer, Thomas
Griffith University Author(s)
Primary Supervisor
Other Supervisors
Editor(s)
Date
2018
Size
File type(s)
Location
License
Abstract

Control systems for human physiotherapy exercises based on functional electrical stimulation (FES) have provided excellent performance in several setups. Myocontrolled neuro-prostheses use electromyography (EMG) for timing and intensity control of stimulation applied to these exercises, estimating not only the volitional activity (from the patient) but also the evoked activity (from FES). A typical EMG response to FES starts with the stimulation artifact, followed by an excitation curve called M-wave. To extract volitional and evoked components, we first need to find the inter-pulse-intervals (IPIs), i.e., the EMG signal between stimulation artifacts. For that, we have developed a method for two-channel stimulation artifact detection for EMG signals which are not hardware-synchronized to a FES stimulator. First, the artifact detection approach marks all potential artifacts based on one of three adaptive threshold-based detection methods (mean/standard deviation, median/MAD and quantiles). Subsequently, for IPI extraction we cluster the potential stimulation artifacts to cross-correlate the resulting potential stimulation artifact vector with a vector of expected artifacts based on the stimulation and EMG frequencies. For evaluation, we performed tests on two benchmark datasets obtained from FES-assisted walking with two hardware setups. We found more than 95% success rate for both hardware setups using the adaptive threshold method independently on the selected method for choosing the threshold. Because of its low computational demands, we recommend the mean/standard deviation approach.

Journal Title

IFAC-PapersOnLine

Conference Title
Book Title
Edition
Volume

51

Issue

27

Thesis Type
Degree Program
School
Publisher link
Patent number
Funder(s)
Grant identifier(s)
Rights Statement
Rights Statement

© 2018 IFAC-PapersOnLine. The attached file is reproduced here in accordance with the copyright policy of the publisher. Please refer to the conference's website for access to the definitive, published version.

Item Access Status
Note
Access the data
Related item(s)
Subject

Clinical sciences

Sports science and exercise

Sports science and exercise not elsewhere classified

Persistent link to this record
Citation

de Sousa, ACC; Valtin, M; Bó, APL; Schauer, T, Automatic Detection of Stimulation Artifacts to Isolate Volitional from Evoked EMG Activity, IFAC-PapersOnLine, 2018, 51 (27), pp. 282-287