Hypoxic Corneal Changes following Eight Hours of Scleral Contact Lens Wear

Loading...
Thumbnail Image
File version

Accepted Manuscript (AM)

Author(s)
Vincent, Stephen J
Alonso-Caneiro, David
Collins, Michael J
Beanland, Alison
Lam, Linda
Lim, Ching Chong
Loke, Alyssa
Nhi, Nguyen
Griffith University Author(s)
Primary Supervisor
Other Supervisors
Editor(s)
Date
2016
Size
File type(s)
Location
License
Abstract

Copyright © 2016 American Academy of Optometry. Purpose. To examine the change in corneal thickness and posterior curvature following 8 hours of miniscleral contact lens wear. Methods. Scheimpflug imaging (Pentacam HR; Oculus) was captured before, and immediately following, 8 hours of miniscleral contact lens wear for 15 young (mean age 22 T 3 years), healthy participants with normal corneae. Natural diurnal variations were considered by measuring baseline corneal changes obtained on a separate control day without contact lens wear. Results. Over the central 6 mm of the cornea, a small but highly statistically significant amount of edema was observed following 8 hours of miniscleral lens wear, after accounting for normal diurnal fluctuations (mean T standard deviation percentage swelling 1.70 T 0.98%, p < 0.0001). Posterior corneal topography remained stable following lens wear (j0.01 ± 0.07 mm steepening over the central 6 mm, p = 0.60). The magnitude of posterior corneal topographical changes following lens wear did not correlate with the extent of lens-related corneal edema (r = j0.16, p = 0.57). Similarly, the initial central corneal vault (maximum post-lens tear layer depth) was not associated with corneal swelling following lens removal (r = 0.27, p = 0.33). Conclusions. Although a small amount of corneal swelling was induced following 8 hours of miniscleral lens wear (on average <2%), modern high Dk miniscleral contact lenses that vault the cornea do not induce clinically significant corneal edema or hypoxic-related posterior corneal curvature changes during short-Term wear. Longer-Term studies of compromised eyes (e.g. corneal ectasia) are still required to inform the optimum lens and fitting characteristics for safe scleral lens wear to minimize corneal hypoxia.

Journal Title

Optometry and Vision Science

Conference Title
Book Title
Edition
Volume

93

Issue

3

Thesis Type
Degree Program
School
Publisher link
Patent number
Funder(s)
Grant identifier(s)
Rights Statement
Rights Statement

© 2016 LWW. This is a non-final version of an article published in final form in Optometry and Vision Science, 016, 93 (3), pp. 293-299. Reproduced in accordance with the copyright policy of the publisher. Please refer to the journal link for access to the definitive, published version.

Item Access Status
Note
Access the data
Related item(s)
Subject

Biomedical and clinical sciences

Science & Technology

Life Sciences & Biomedicine

Ophthalmology

miniscleral contact lens

corneal edema

Persistent link to this record
Citation

Vincent, SJ; Alonso-Caneiro, D; Collins, MJ; Beanland, A; Lam, L; Lim, CC; Loke, A; Nhi, N, Hypoxic Corneal Changes following Eight Hours of Scleral Contact Lens Wear, Optometry and Vision Science, 2016, 93 (3), pp. 293-299