Intra-operative error during Austin Moore hemiarthroplasty
File version
Author(s)
Griffith University Author(s)
Primary Supervisor
Other Supervisors
Editor(s)
Date
Size
232391 bytes
File type(s)
application/pdf
Location
License
Abstract
PURPOSE: To examine the frequency of technical errors during implantation of the Austin Moore prosthesis in a public hospital.
METHODS: Radiographs and charts of 147 consecutive uncemented Austin Moore hemiarthoplasty patients were retrospectively reviewed with particular reference to intra-operative errors associated with early failure of the prosthesis.
RESULTS: 48% of the patients had at least one error pertinent to implantation and 14% sustained intra-operative fractures. The error rates between relatively junior doctors and consultants were not significantly different.
CONCLUSION: The uncemented Austin Moore prosthesis is a technically demanding prosthesis that is difficult to implant well. Greater selectivity should be exercised when considering its use for femoral neck fractures.
Journal Title
Journal of Orthopaedic Surgery
Conference Title
Book Title
Edition
Volume
14
Issue
3
Thesis Type
Degree Program
School
Publisher link
DOI
Patent number
Funder(s)
Grant identifier(s)
Rights Statement
Rights Statement
© 2006 Journal of Orthopaedic Surgery. The attached file is reproduced here in accordance with the copyright policy of the publisher. Please refer to the journal's website for access to the definitive, published version.