Automatic generation of knee kinematic models from medical imaging
File version
Version of Record (VoR)
Author(s)
Barzan, M
Nasseri, A
Maharaj, JN
Diamond, LE
Saxby, DJ
Griffith University Author(s)
Primary Supervisor
Other Supervisors
Editor(s)
Date
Size
File type(s)
Location
Abstract
Background and Objective: Three-dimensional spatial mechanisms have been used to accurately predict passive knee kinematics, and have shown potential to be used in optimized multibody kinematic models. Such multi-body models are anatomically consistent and can accurately predict passive knee kinematics, but require extensive medical image processing and thus are not widely adopted. This study aimed to automate the generation of kinematic models of tibiofemoral (TFJ) and patellofemoral (PFJ) joints from segmented magnetic resonance imaging (MRI) and compare them against a corresponding manual pipeline. Methods: From segmented MRI of eight healthy participants (four females; aged 14.0 ± 2.6 years), geometric parameters (i.e., articular surfaces, ligament attachments) were determined both automatically and manually, and then assembled into TFJ and PFJ kinematic models to predict passive kinematics. The TFJ model was a six-link mechanism with deformable ligamentous constraints, whereas PFJ was a modified hinge. The ligament length changes through TFJ flexion were prescribed to literature strain profile. The geometric parameters were optimized to ensure physiological kinematic predictions through a Multiple Objective Particle Swarm Optimization. Results: Geometric parameters showed strong agreement between automatic and manual pipelines (median error of 2.8 mm for anatomical landmarks and 1.5 mm for ligament lengths). Predicted TFJ and PFJ kinematics from the two pipelines were not statistically different, except for tibial superior/inferior translation near terminal TFJ extension. The TFJ kinematics predicted from the automatic pipeline had mean errors of 3.6° and 12.4° for adduction/abduction and internal/external rotation, respectively, and <7 mm mean translational error compared to the manual pipeline. Predicted PFJ had <9° mean rotational errors and <6 mm mean translational errors. Conclusions: The automatic pipeline developed and presented here can predict passive knee kinematics comparable to a manual pipeline, but removes laborious manual processing and provides a systematic approach to model creation.
Journal Title
Computer Methods and Programs in Biomedicine
Conference Title
Book Title
Edition
Volume
256
Issue
Thesis Type
Degree Program
School
Publisher link
Patent number
Funder(s)
Grant identifier(s)
Rights Statement
Rights Statement
© 2024 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/)
Item Access Status
Note
Access the data
Related item(s)
Subject
Biomedical imaging
Biomedical engineering
Applied computing
Computer vision and multimedia computation
Persistent link to this record
Citation
Shi, B; Barzan, M; Nasseri, A; Maharaj, JN; Diamond, LE; Saxby, DJ, Automatic generation of knee kinematic models from medical imaging, Computer Methods and Programs in Biomedicine, 2024, 256, pp. 108370