Reliability of hip muscle strength measured in principal and intermediate planes of movement
File version
Version of Record (VoR)
Author(s)
Saxby, David J
Kositsky, Adam
Barrett, Rod S
Diamond, Laura E
Griffith University Author(s)
Primary Supervisor
Other Supervisors
Editor(s)
Date
Size
File type(s)
Location
Abstract
Background. Muscle strength testing is widely used in clinical and athletic populations. Commercially available dynamometers are designed to assess strength in three principal planes (sagittal, transverse, frontal). However, the anatomy of the hip suggests muscles may only be recruited submaximally during tasks performed in these principal planes. Objective. To evaluate the inter-session reliability of maximal isometric hip strength in the principal planes and three intermediate planes. Methods. Twenty participants (26.1 ± 2.7 years, 50% female) attended two testing sessions 6.2 ± 1.8 days apart. Participants completed 3-5 maximal voluntary isometric contractions for hip abduction, adduction, flexion, extension, and internal and external rotation measured using a fixed uniaxial load cell (custom rig) and commercial dynamometer (Biodex). Three intermediate hip actions were also tested using the custom rig: Extension with abduction, extension with external rotation, and extension with both abduction and external rotation. Results. Moderate-to-excellent intraclass correlation coefficients were observed for all principal and intermediate muscle actions using the custom rig (0.72-0.95) and the Biodex (0.85-0.95). The minimum detectable change was also similar between devices (custom rig D 11-31%; Biodex = 9-20%). Bland-Altman analysis revealed poor agreement between devices (range between upper and lower limits of agreement = 77-131%). Conclusions. Although the custom rig and Biodex showed similar reliability, both devices may lack the sensitivity to detect small changes in hip strength commonly observed following intervention.
Journal Title
PeerJ
Conference Title
Book Title
Edition
Volume
9
Issue
Thesis Type
Degree Program
School
Publisher link
Patent number
Funder(s)
Grant identifier(s)
Rights Statement
Rights Statement
© 2021 Goncalves et al. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Item Access Status
Note
Access the data
Related item(s)
Subject
Biological sciences
Biomedical and clinical sciences
Science & Technology
Multidisciplinary Sciences
Science & Technology - Other Topics
Muscle function
Dynamometer
Persistent link to this record
Citation
Goncalves, BAM; Saxby, DJ; Kositsky, A; Barrett, RS; Diamond, LE, Reliability of hip muscle strength measured in principal and intermediate planes of movement, PeerJ, 2021, 9