Accuracy of dual-energy x-ray absorptiometry for assessing longitudinal change in visceral adipose tissue in patients with coronary artery disease

No Thumbnail Available
File version
Author(s)
Taylor, Jenna L
Holland, David J
Coombes, Jeff S
Keating, Shelley E
Griffith University Author(s)
Primary Supervisor
Other Supervisors
Editor(s)
Date
2021
Size
File type(s)
Location
License
Abstract

BACKGROUND/OBJECTIVE: Visceral adipose tissue (VAT) is a key target of interventions for obesity-related diseases. Dual-energy x-ray absorptiometry (DXA) can estimate VAT, however its accuracy to measure longitudinal change in VAT compared to gold-standard techniques such as magnetic resonance imaging (MRI), has not been studied in adults. This study aimed to determine the accuracy of DXA compared with gold-standard MRI for cross-sectional VAT assessment, and for detecting longitudinal change in VAT. METHODS: Adults with coronary artery disease (64 ± 8 years; BMI 27.8 ± 3.5 kg/m2; 88% male) were assessed for VAT by DXA and MRI at baseline (n = 34) and during implementation of an exercise intervention study at 3- and 12-months (n = 29). To match the 5.2 cm DXA measurement site for Hologic software (InnerCoreTM), VAT cross-sectional area (CSA) was measured by MRI using a single slice at L4/L5 junction, and VAT volume measured by 10 × 5 mm slices over the L4/L5 junction. MRI slices were quantified for VAT using semi-automated specialised software. Relationships between DXA and MRI for cross-sectional VAT and longitudinal change in VAT were determined by linear regression. Accuracy between the methods was assessed by Bland-Altman analysis, with data presented as mean difference (95% confidence interval), lower and upper limits of agreement (LoA). RESULTS: Strong correlations were found between DXA-VAT and MRI-VAT at baseline (r = 0.90; p < 0.001), and longitudinal change in DXA-VAT and MRI-VAT over 3- and 12-months (r = 0.67; p < 0.001). In contrast, Bland-Altman analysis revealed significant overestimation by DXA-VAT volume at baseline by 13% [-104 cm3 (-157, -52 cm3), p < 0.001; LoA (-398, 189 cm3)], and underestimation of change in DXA-VAT volume over 3-months by 33% [-41 cm3 (-77, -4 cm3), p = 0.030; LoA (-228, 147 cm3)] and 12-months by 47% [-65 cm3 (-114, -17 cm3), p = 0.010; LoA (-316, 185 cm3)]. Results were similar for VAT CSA. CONCLUSIONS: Compared with MRI, DXA substantially underestimated longitudinal changes in VAT. Therefore, DXA is not currently a valid alternative to MRI for quantifying VAT changes and may under-represent the effectiveness of interventions for obesity management.

Journal Title

International Journal of Obesity

Conference Title
Book Title
Edition
Volume
Issue
Thesis Type
Degree Program
School
Publisher link
Patent number
Funder(s)
Grant identifier(s)
Rights Statement
Rights Statement
Item Access Status
Note

This publication has been entered as an advanced online version in Griffith Research Online.

Access the data
Related item(s)
Subject

Biomedical and clinical sciences

Education

Persistent link to this record
Citation

Taylor, JL; Holland, DJ; Coombes, JS; Keating, SE, Accuracy of dual-energy x-ray absorptiometry for assessing longitudinal change in visceral adipose tissue in patients with coronary artery disease, International Journal of Obesity, 2021

Collections