Safety and efficacy of peripheral versus centrally administered vasopressor infusion: A single-centre retrospective observational study
File version
Author(s)
Efendy, Rachel
Apte, Yogesh
Craswell, Alison
Lin, Frances
Ramanan, Mahesh
Griffith University Author(s)
Primary Supervisor
Other Supervisors
Editor(s)
Date
Size
File type(s)
Location
License
Abstract
Background: Shock affects one-third of patients admitted to intensive care and is associated with increased mortality. Vasopressor medications are used to maintain blood pressure in shock. Central venous catheters are associated with serious complications and pose logistical difficulties for insertion. Delivery of vasopressors via peripheral intravenous cannula may be a safe alternative.
Methods: This is a retrospective cohort study comparing safety profile and outcomes of vasopressor delivery via peripheral and central routes in critically ill patients over a 12-month period in a mixed medical-surgical intensive care unit. Demographics, clinical characteristics, treatments, and safety outcome data were extracted from medical records. Patients were classified into three groups: vasopressor infusions via peripheral intravenous cannula, combined peripheral intravenous cannula followed by central venous catheter, and central venous catheter only. Groups were compared using the Kruskal–Wallis test for continuous variables and Fisher's exact test for categorical variables. The impact of duration of vasopressor infusion on complication rates was assessed using logistic regression.
Results: We identified 212 patients who received vasopressor infusion, 39 received via peripheral only (Group 1), 155 via peripheral followed by central (Group 2), and 18 via central only (Group 3). There were some baseline differences between groups. Group 1 had the lowest median Acute Physiology and Chronic Health Evaluation III score (64, interquartile range = 44–77), and Group 3, the highest (86, interquartile range = 57–101). Duration of vasopressor infusion was shortest in Group 1 and longer in Groups 2 and 3. There were no major complications; however, minor complications such as leakage, extravasation, and erythema occurred in 41% of Group 1 and 28% of Group 2 patients. Duration of peripheral vasopressor infusion was not associated with an increased risk of complications.
Conclusions: Administration of vasopressor infusions for short duration in critically ill patients via a peripheral venous cannula may be feasible, with low rates of complications, and offers a safe alternative to central venous access.
Journal Title
Australian Critical Care
Conference Title
Book Title
Edition
Volume
35
Issue
5
Thesis Type
Degree Program
School
Publisher link
Patent number
Funder(s)
Grant identifier(s)
Rights Statement
Rights Statement
Item Access Status
Note
Access the data
Related item(s)
Subject
Clinical sciences
Nursing
Intensive care
Persistent link to this record
Citation