Rotary ventricular assist devices (VADs) operated clinically under constant speed control (CSC) cannot respond adequately to changes in patient cardiac demand, resulting in sub‐optimal VAD flow regulation. Starling‐like control (SLC) of VADs mimics the healthy ventricular flow regulation and automatically adjusts VAD speed to meet varying patient cardiac demand. The use of a fixed control line (CL – the relationship between ventricular preload and VAD flow) limits the flow regulating capability of the controller, especially in the case of exercise. Adaptive SLC (ASLC) overcomes this limitation by allowing the controller to adapt the CL to meet a diverse range of circulatory conditions. This study evaluated ASLC, SLC and CSC in a biventricular supported mock circulation loop under the simulated conditions of exercise, sleep, fluid loading and systemic hypertension. Each controller was evaluated on its ability to remain within predefined limits of VAD flow, preload, and afterload. The ASLC produced superior cardiac output (CO) during exercise (10.1 L/min) compared to SLC (7.3 L/min) and CSC (6.3 L/min). The ASLC produced favourable haemodynamics during sleep, fluid loading and systemic hypertension and could remain within a predefined haemodynamic range in three out of four simulations, suggesting improved haemodynamic performance over SLC and CSC.

Journal Title

Artificial Organs

Conference Title
Book Title
Edition
Volume
Issue
Thesis Type
Degree Program
School
Publisher link
Patent number
Funder(s)
Grant identifier(s)
Rights Statement
Rights Statement

© 2019 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc. This is the peer reviewed version of the following article: In‐Vitro evaluation of an adaptive Starling‐like controller for dual Rotary ventricular assist devices, Artificial Organs, which has been published in final form at 10.1111/aor.13510. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Self-Archiving (http://olabout.wiley.com/WileyCDA/Section/id-828039.html)

Item Access Status
Note
Access the data
Related item(s)
Subject

Biomedical engineering

Clinical sciences

Persistent link to this record
Citation
Collections