A novel echocardiographic parameter considering left ventricular afterload during V-A ECMO support

Loading...
Thumbnail Image
File version

Version of Record (VoR)

Author(s)
Sato, Kei
Heinsar, Silver
Chan, Jonathan
Farah, Samia M
Wildi, Karin
Obonyo, Nchafatso G
Liu, Keibun
Ainola, Carmen
Sato, Noriko
Abbate, Gabriella
Wilson, Emily S
Bouquet, Mahé
Hyslop, Kieran
Passmore, Margaret R
Ijuin, Shinichi
et al.
Griffith University Author(s)
Primary Supervisor
Other Supervisors
Editor(s)
Date
2024
Size
File type(s)
Location
Abstract

Background Left ventricular stroke work index (LVSWI) and cardiac power index (CPI) account for the haemodynamic load of the left ventricle and are promising prognostic values in cardiogenic shock. However, accurately and non-invasively measuring these parameters during veno-arterial extracorporeal membrane oxygenation (V-A ECMO) is challenging and potentially biased by the extracorporeal circulation. This study aimed to investigate, in an ovine model of cardiogenic shock, whether Pressure-Strain Product (PSP), a novel speckle-tracking echocardiography parameter, (1) can correlate with pressure-volume catheter-based LVSWI and CPI, and (2) can be load-independent during the flow modification of V-A ECMO.

Methods Nine Dorset-cross ewes (51 ± 4 kg) were included. After cardiogenic shock was induced, full support V-A ECMO (X L/min based on 60 mL/kg/min) commenced. At seven time points during 24-h observation, echocardiographic parameters as well as pressure-volume catheter-based LVSWI and CPI were simultaneously measured with X and following X-1 L/min of ECMO flow. PSP was calculated by multiplying global circumferential strain or global radial strain, and mean arterial pressure, for PSPcirc or PSPrad, respectively.

Results PSPcirc showed a stronger correlation with LVSWI (correlation coefficient, CC = .360, p < .001) and CPI (CC = .283, p < .001) than other echocardiographic parameters. The predictability of PSPcirc for pressure-volume catheter-based LVSWI (AUC .82) and CPI (AUC .80) was also higher than other echocardiographic parameters. No statistically significant differences were identified between the two ECMO flow variations in PSPcirc (p = .558).

Conclusions A novel echocardiographic parameter, PSP, may non-invasively predict pressure-volume catheter-based LVSWI and CPI in a load-independent manner in a cardiogenic shock supported by V-A ECMO.

Journal Title

European Journal of Clinical Investigation

Conference Title
Book Title
Edition
Volume
Issue
Thesis Type
Degree Program
School
Publisher link
Patent number
Funder(s)
Grant identifier(s)
Rights Statement
Rights Statement

© 2024 The Author(s). European Journal of Clinical Investigation published by John Wiley & Sons Ltd on behalf of Stichting European Society for Clinical Investigation Journal Foundation. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.

Item Access Status
Note

This publication has been entered in Griffith Research Online as an advance online version.

Access the data
Related item(s)
Subject

Cardiovascular medicine and haematology

Clinical sciences

Persistent link to this record
Citation

Sato, K; Heinsar, S; Chan, J; Farah, SM; Wildi, K; Obonyo, NG; Liu, K; Ainola, C; Sato, N; Abbate, G; Wilson, ES; Bouquet, M; Hyslop, K; Passmore, MR; Ijuin, S; et al., A novel echocardiographic parameter considering left ventricular afterload during V-A ECMO support, European Journal of Clinical Investigation, 2024, pp. e14263

Collections