Invasive device-associated skin complications and mechanical dysfunctions in paediatric healthcare: A systematic review and meta-analysis

Loading...
Thumbnail Image
File version

Version of Record (VoR)

Author(s)
Takashima, Mari
Hyun, Areum
Gibson, Victoria
Borello, Eloise
Ullman, Amanda
Griffith University Author(s)
Primary Supervisor
Other Supervisors
Editor(s)
Date
2024
Size
File type(s)
Location
Abstract

Aim This study aimed to estimate the proportion and rate of skin complications and mechanical dysfunction associated with indwelling invasive devices in paediatric healthcare.

Design This systematic review is reported in accordance with Cochrane standards for randomized controlled trials and the Meta-analysis of Observation Studies in Epidemiology for cohort studies.

Data Sources MEDLINE, CINAHL, Embase, Web of Science, Scopus, Cochrane CENTRAL, clinical trial registries, and unpublished study databases were searched.

Review Methods Cohort studies and trials published from January 2011 to June 2022, including (1) indwelling invasive devices, (2) paediatric participants admitted to a hospital, (3) reporting post-insertion device-associated skin complication and/or mechanical dysfunction, and (4) published in English, were included. Device-associated skin complication and mechanical dysfunction (infiltration, leakage, occlusion/blockage, dislodgement/malposition, breakage and others). Pooled proportion and incidence rate per 1000 device days are reported.

Results This review synthesized 114 studies (30,782 devices; 1,635,649 device-days). Skin complications were reported in 40 studies, but none exclusively reported individual device-related pressure injuries. Mechanical dysfunctions were well-reported for central venous access devices, peripheral intravenous catheters, nasogastric/gastric tubes and peritoneal dialysis catheters but less for arterial catheters, extracorporeal membrane oxygenation and ventricular assist devices.

Conclusions This systematic review highlights the need for standardized definitions and reporting methods to better surveil and benchmark device-related complications, particularly for understudied device types. Device-related pressure injuries were not reported in any of the included studies, and all devices except for vascular access devices require standardized reporting of complications.

Impact Despite the widespread use of invasive devices, comprehensive data on their prevalence, utility, and associated paediatric complications is limited. This review identified prevalent skin complications, occlusions and dislodgments in children with devices, underscoring the need for standardized reporting to enhance surveillance and understanding of paediatric device-related complications.

Journal Title

Journal of Advanced Nursing

Conference Title
Book Title
Edition
Volume
Issue
Thesis Type
Degree Program
School
Publisher link
Patent number
Funder(s)
Grant identifier(s)
Rights Statement
Rights Statement

© 2024 The Authors. Journal of Advanced Nursing published by John Wiley & Sons Ltd. This is an open access article under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.

Item Access Status
Note

This publication has been entered in Griffith Research Online as an advance online version.

Access the data
Related item(s)
Subject

Midwifery

Nursing

Persistent link to this record
Citation

Takashima, M; Hyun, A; Gibson, V; Borello, E; Ullman, A, Invasive device-associated skin complications and mechanical dysfunctions in paediatric healthcare: A systematic review and meta-analysis, Journal of Advanced Nursing, 2024