Particle and bioaerosol characteristics in a paediatric intensive care unit

No Thumbnail Available
File version
Author(s)
He, Congrong
Mackay, Ian M
Ramsay, Kay
Liang, Zhen
Kidd, Timothy
Knibbs, Luke D
Johnson, Graham
McNeale, Donna
Stockwelle, Rebecca
Coulthard, Mark G
Long, Debbie A
Williams, Tara J
Duchaine, Caroline
Smith, Natalie
Wainwright, Claire
Morawska, Lidia
Griffith University Author(s)
Primary Supervisor
Other Supervisors
Editor(s)
Date
2017
Size
File type(s)
Location
License
Abstract

The paediatric intensive care unit (PICU) provides care to critically ill neonates, infants and children. These patients are vulnerable and susceptible to the environment surrounding them, yet there is little information available on indoor air quality and factors affecting it within a PICU. To address this gap in knowledge we conducted continuous indoor and outdoor airborne particle concentration measurements over a two-week period at the Royal Children's Hospital PICU in Brisbane, Australia, and we also collected 82 bioaerosol samples to test for the presence of bacterial and viral pathogens. Our results showed that both 24-hour average indoor particle mass (PM10) (0.6–2.2 μg m− 3, median: 0.9 μg m− 3) and submicrometer particle number (PN) (0.1–2.8 × 103 p cm− 3, median: 0.67 × 103 p cm− 3) concentrations were significantly lower (p < 0.01) than the outdoor concentrations (6.7–10.2 μg m− 3, median: 8.0 μg m− 3 for PM10 and 12.1–22.2 × 103 p cm− 3, median: 16.4 × 103 p cm− 3 for PN). In general, we found that indoor particle concentrations in the PICU were mainly affected by indoor particle sources, with outdoor particles providing a negligible background. We identified strong indoor particle sources in the PICU, which occasionally increased indoor PN and PM10 concentrations from 0.1 × 103 to 100 × 103 p cm− 3, and from 2 μg m− 3 to 70 μg m− 3, respectively. The most substantial indoor particle sources were nebulization therapy, tracheal suction and cleaning activities. The average PM10 and PN emission rates of nebulization therapy ranged from 1.29 to 7.41 mg min− 1 and from 1.20 to 3.96 p min− 1 × 1011, respectively. Based on multipoint measurement data, it was found that particles generated at each location could be quickly transported to other locations, even when originating from isolated single-bed rooms. The most commonly isolated bacterial genera from both primary and broth cultures were skin commensals while viruses were rarely identified. Based on the findings from the study, we developed a set of practical recommendations for PICU design, as well as for medical and cleaning staff to mitigate aerosol generation and transmission to minimize infection risk to PICU patients.

Journal Title

Environment International

Conference Title
Book Title
Edition
Volume

107

Issue
Thesis Type
Degree Program
School
Publisher link
Patent number
Funder(s)
Grant identifier(s)
Rights Statement
Rights Statement
Item Access Status
Note
Access the data
Related item(s)
Subject

Paediatrics

Science & Technology

Life Sciences & Biomedicine

Environmental Sciences

Environmental Sciences & Ecology

Airborne particle number and mass

Persistent link to this record
Citation

He, C; Mackay, IM; Ramsay, K; Liang, Z; Kidd, T; Knibbs, LD; Johnson, G; McNeale, D; Stockwelle, R; Coulthard, MG; Long, DA; Williams, TJ; Duchaine, C; Smith, N; Wainwright, C; Morawska, L, Particle and bioaerosol characteristics in a paediatric intensive care unit, Environment International, 2017, 107, pp. 89-99

Collections