Custom extraction of macular ganglion cell-inner plexiform layer thickness more precisely co-localizes structural measurements with visual fields test grids

Loading...
Thumbnail Image
File version

Version of Record (VoR)

Author(s)
Tong, J
Alonso-Caneiro, D
Yoshioka, N
Kalloniatis, M
Zangerl, B
Griffith University Author(s)
Primary Supervisor
Other Supervisors
Editor(s)
Date
2020
Size
File type(s)
Location
Abstract

We aimed to evaluate methods of extracting optical coherence tomography (OCT)-derived macular ganglion cell-inner plexiform layer (GCIPL) thickness measurements over retinal locations corresponding to standard visual field (VF) test grids. A custom algorithm was developed to automatically extract GCIPL thickness measurements from locations corresponding to Humphrey Field Analyser 10-2 and 30-2 test grids over Goldmann II, III and V stimulus sizes from a healthy cohort of 478 participants. Differences between GCIPL thickness measurements based on VF test grids (VF-based paradigms) and the 8 × 8 grid, as per instrument review software, were analyzed, as were impacts of fovea to optic disc tilt and areas over which GCIPL thickness measurements were extracted. Significant differences between the VF-based paradigms and the 8 × 8 grid were observed at up to 55% of locations across the macula, with the greatest deviations at the fovea (median 25.5 μm, 95% CI 25.24–25.72 μm, P <.0001). While significant correlations with fovea to optic disc tilt were noted at up to 33% of locations distributed 6°–8° from the foveal center, there were no marked differences in GCIPL thickness measurements between VF-based paradigms using different stimulus sizes. As such, standard high-density OCT measurement paradigms do not adequately reflect GCIPL measurements at retinal locations tested with standard VF patterns, with the central macular region contributing most to the observed differences and with further correction required for fovea to optic disc tilt. Spatial direction of GCIPL thickness measurements will improve future comparisons of structure and function, thereby improving methods designed to detect pathology affecting the inner retina.

Journal Title

Scientific Reports

Conference Title
Book Title
Edition
Volume

10

Issue

1

Thesis Type
Degree Program
School
Publisher link
Patent number
Funder(s)
Grant identifier(s)
Rights Statement
Rights Statement

© The Author(s) 2020. This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made.

Item Access Status
Note
Access the data
Related item(s)
Subject

Ophthalmology and optometry

Applied statistics

Persistent link to this record
Citation

Tong, J; Alonso-Caneiro, D; Yoshioka, N; Kalloniatis, M; Zangerl, B, Custom extraction of macular ganglion cell-inner plexiform layer thickness more precisely co-localizes structural measurements with visual fields test grids, Scientific Reports, 2020, 10 (1), pp. 18527

Collections