Peripherally Inserted Central Catheter (PICC) Insertion Success and Optimal Placement with New Technology: A Pre-Post Cohort Study

Loading...
Thumbnail Image
File version

Accepted Manuscript (AM)

Author(s)
Nicholas, Megan
Larsen, Emily N
Rickard, Claire M
Mihala, Gabor
Groom, Peter
Marsh, Nicole
Griffith University Author(s)
Primary Supervisor
Other Supervisors
Editor(s)
Date
2021
Size
File type(s)
Location
Abstract

Background: Peripherally inserted central catheters (PICCs) are commonly placed with the assistance of fluoroscopy or medical imaging, ultrasound, electrocardiogram guidance, or all the above. Innovative ultrasound technologies continue to emerge; however, the impact upon clinical outcomes is not well understood. In this study, we aimed to compare outcomes of an existing ultrasound system with SHERLOCK 3CG™ Tip Confirmation (preintervention) to an updated SHERLOCK 3CG Diamond Tip Confirmation system, incorporating catheter-to-vein ratio measurement capabilities and an advanced magnetic-based tip navigation system (postintervention).

Methods: In this prospective pre-post cohort study, we recruited adult patients requiring a new PICC. The study was conducted at a quaternary hospital in Queensland, Australia. Data were collected between May 2017 (4 months before equipment introduction) and January 2018 (4 months after equipment introduction), with a 1-month exclusion (education or learning) period in between. Patient, PICC, and device removal details were collected. The primary outcome was first-time insertion success, defined as successful PICC insertion after a single attempt (skin puncture), with the tip confirmed in an optimal location by the navigation system and a subsequent chest x-ray (as per hospital policy).

Results: There were 503 participants with patient demographics and PICC characteristics balanced between the preintervention (n = 266) and postintervention (n = 237) groups. First-time insertion success was higher in the preintervention group (203/255, 80%) than the postintervention group (166/226, 73%), but this was not statistically significant (risk ratio = 0.92, 95% confidence interval = 0.83–1.02).

Conclusions: There was no change in clinical outcomes with the use of next-generation ultrasound technology. These results justify future large studies and subsequent review into the efficacy of tip-confirmation systems and processes to maintain patient safety.

Journal Title

Journal of the Association for Vascular Access

Conference Title
Book Title
Edition
Volume

26

Issue

1

Thesis Type
Degree Program
School
Publisher link
Patent number
Funder(s)
Grant identifier(s)
Rights Statement
Rights Statement

© 2021 Association for Vascular Access. Published by Elsevier Ltd. Licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International Licence (http://creativecommons.org/licenses/by-nc-nd/4.0/) which permits unrestricted, non-commercial use, distribution and reproduction in any medium, providing that the work is properly cited.

Item Access Status
Note
Access the data
Related item(s)
Subject

Nursing

Cardiovascular medicine and haematology

Persistent link to this record
Citation

Nicholas, M; Larsen, EN; Rickard, CM; Mihala, G; Groom, P; Marsh, N, Peripherally Inserted Central Catheter (PICC) Insertion Success and Optimal Placement with New Technology: A Pre-Post Cohort Study, Journal of the Association for Vascular Access, 2021, 26 (1), pp. 39-46

Collections