7-Tesla Cardiac MRI for Ventricular and Valvular quantitation in healthy volunteers
File version
Author(s)
Staeb, D
O'Brien, K
Galloway, G
Barth, M
Griffith University Author(s)
Primary Supervisor
Other Supervisors
Editor(s)
Date
Size
File type(s)
Location
Munich, Germany
License
Abstract
Background: Ultra-high-field (B0 ≥7 Tesla) cardiovascular magnetic resonance (CMR) offers increased resolution, but cardiac imaging requiring ECG gating is significantly impacted from the magneto-hydrodynamic (MHD) effect, distorts the ECG trace (1–3). Previously, 7T CMR was constrained to using pulse oximetry for triggering, We explored the technical feasbility of a 7 T research MR scanner using of-the-art ECG trigger algorithm to assess left and right ventricular volumes, aortic and pulmonary valve flow.
Methods: 7T CMR scans were performed on 10 healthy volunteers on whole-body research MRI scanner (Siemens Healthcare, Erlangen, Germany) with 8 channel Tx/32 channel Rx cardiac coil (MRI Tools GmbH, Berlin, Germany) under institutional review board approval. Vectorcardiogram ECG was successfully performed using a learning phase outside of the magnetic field, with a trigger algorithm with sufficient accuracy for CMR despite severe ECG signal distortions from the 7T field. Cine CMR was performed after 3rd-order B0 shimming using a high-resolution breath-held ECG-retro-gated segmented two-dimensional spoiled gradient echo sequence, and 2-dimensional phase contrast flow imaging. Analysis was performed using Cmr42 software (Circle CVi, Calgary).
Results: Successful 7T CMR scans were acquired in all patients (100%) using the Vectorcardiogram 3-lead ECG method. Image quality was sufficient to quantitate both left and right ventricular volumes, ejection fraction, aortic and pulmonary blood flow and regurgitant fractions in 9/10 (90%) of volunteers (figure 1), with one volunteer having difficulty with breath-holding and ventricular ectopy causing gating artefacts.
Journal Title
Conference Title
European Heart Journal
Book Title
Edition
Volume
39
Issue
suppl_1
Thesis Type
Degree Program
School
Publisher link
Patent number
Funder(s)
Grant identifier(s)
Rights Statement
Rights Statement
Item Access Status
Note
Access the data
Related item(s)
Subject
Cardiovascular medicine and haematology
Clinical sciences
Science & Technology
Life Sciences & Biomedicine
Cardiac & Cardiovascular Systems
Cardiovascular System & Cardiology
Persistent link to this record
Citation
Hamilton-Craig, C; Staeb, D; O'Brien, K; Galloway, G; Barth, M, 7-Tesla Cardiac MRI for Ventricular and Valvular quantitation in healthy volunteers, European Heart Journal, 2018, 39 (suppl_1), pp. 233-233