From insertion to removal: A multicenter survival analysis of an admitted cohort with peripheral intravenous catheters inserted in the emergency department

No Thumbnail Available
File version
Author(s)
Carr, Peter J
Rippey, James CR
Cooke, Marie L
Higgins, Niall S
Trevenen, Michelle
Foale, Aileen
Rickard, Claire M
Griffith University Author(s)
Primary Supervisor
Other Supervisors
Editor(s)
Date
2018
Size
File type(s)
Location
License
Abstract

Background:

Most patients admitted to the hospital via the emergency department (ED) do so with a peripheral intravenous catheter/cannula (PIVC). Many PIVCs develop postinsertion failure (PIF). Objective:

To determine the independent factors predicting PIF after PIVC insertion in the ED. Methods:

We analyzed data from a prospective clinical cohort study of ED-inserted PIVCs admitted to the hospital wards. Independent predictors of PIF were identified using Cox proportional hazards regression modeling. Results:

In 391 patients admitted from 2 EDs, the rate of PIF was 31% (n=118). The types of PIF identified were infiltration, occlusion, pain and/or peripheral intravenous assessment score >2 (ie, the hospital’s assessment of PIVC phlebitis), and dislodgement (ie, accidental securement device failure or purposeful removal). Of the PIVCs that failed, infiltration and occlusion combined were the most common causes of PIF (n=55, 47%). The median PIVC dwell time was 28.5 hours (interquartile range [IQR], 17.4–50.8 hours). The following variables were associated with increased risk of PIF: being an older patient (for a 1-year increase, hazard ratio [HR], 1.02; 95% confidence interval [CI], 1.01–1.03; P=.0001); having an Australian Triage Scale score of 1 or 2 compared to a score of 3, 4, or 5 (HR, 2.04; 95% CI, 1.39–3.01; P=.0003); having an ultrasound-guided PIVC (HR, 6.52; 95% CI, 2.11–20.1; P=.0011); having the PIVC inserted by a medical student (P=.0095); infection prevention breaches at insertion (P=.0326); and PIVC inserted in the ante cubital fossa or the back of hand compared to the upper arm (P=.0337). Conclusion:

PIF remains at an unacceptable level in both traditionally inserted and ultrasound-inserted PIVCs.

Journal Title

Infection Control & Hospital Epidemiology

Conference Title
Book Title
Edition
Volume

39

Issue

10

Thesis Type
Degree Program
School
Publisher link
Patent number
Funder(s)
Grant identifier(s)
Rights Statement
Rights Statement
Item Access Status
Note
Access the data
Related item(s)
Subject

Biomedical and clinical sciences

Acute care

Persistent link to this record
Citation
Collections