Enhanced load frequency control in multi-source power systems with stochastic optimization algorithms and SMES integration via AC-DC parallel tie-lines

No Thumbnail Available
File version
Author(s)
Sarker, Md Shahan
Ahmed, Md Imtiaz
Hossain, Md Alamgir
Islam, Md Rashidul
Hossain, Md Arafat
Sheikh, Md Rafiqul Islam
Griffith University Author(s)
Primary Supervisor
Other Supervisors
Editor(s)
Date
2025
Size
File type(s)
Location
License
Abstract

The integration of renewable energy sources alongside conventional generators introduces challenges in maintaining frequency and power exchange between interconnected regions. To address these complexities and adjust the control parameters, this study investigates the application of three different stochastic optimization algorithmsparticle swarm optimization (PSO), genetic algorithm (GA) and sine cosine algorithm (SCA)-combined with superconducting magnetic energy storage (SMES) technology for improved load frequency control (LFC). The results of integrating SMES technology are evaluated and compared with traditional control approaches in various operating scenarios. For the specific system with SMES, a single Proportional-Integral-Derivative (PID) controller was switched out for three PID controllers, and the results were noted for comparison. The expanded LFC technique effectively maintains optimal power exchange and a steady frequency throughout the linked regions, as demonstrated by the simulation results. This study bridges research gaps by combining advanced optimization algorithms and SMES technology to advance LFC, which is often overlooked in the literature. A comparative analysis under varying conditions confirms the effectiveness of the proposed system. The robustness of the system was validated with parameter variations of ±25 % and ±50 %, demonstrating its adaptability and reliability under dynamic conditions. When SMES was integrated, the deviation of the power of the tie line decreased by 13.59 %, the frequency deviation in area-1 improved by 34.13 %, and the frequency deviation of area-2 improved by 12.57 %. Therefore, the integration of SMES ensures dependable and sturdy performance in multiple power source systems linked by AC-DC parallel tie-lines. The results highlight the efficiency and resilience of the system, confirming its suitability for diverse operating scenarios.

Journal Title

Next Research

Conference Title
Book Title
Edition
Volume

2

Issue

2

Thesis Type
Degree Program
School
Publisher link
Patent number
Funder(s)
Grant identifier(s)
Rights Statement
Rights Statement
Item Access Status
Note
Access the data
Related item(s)
Subject
Persistent link to this record
Citation

Sarker, MS; Ahmed, MI; Hossain, MA; Islam, MR; Hossain, MA; Sheikh, MRI, Enhanced load frequency control in multi-source power systems with stochastic optimization algorithms and SMES integration via AC-DC parallel tie-lines, Next Research, 2025, 2 (2), pp. 100288

Collections