Aim: Haemolysis has a major impact on patient safety as the need for a replacement specimen increases the risk of injury and infection, delays test results and extends the duration of hospital stays. Consistency of haemolysis detection and reporting can facilitate the generation of benchmark data used to develop quality practices to monitor and reduce this leading cause of pre-analytical laboratory error. This review aims to investigate current methods of haemolysis detection and reporting. Method: Due to known heterogeneity and immaturity of the research field, a scoping search was conducted using PUBMED, Embase, Medline and CINAHL. Articles published between 2000 and 2014 that reported haemolysis rates in specimens from the general population were included. Results: Of the 50 studies that met the inclusion criteria, 20 detected haemolysis using the Haemolysis Index (HI), 19 by visual inspection and 13 by undefined methods. There was large intra-study variation in the plasma free haemoglobin level used to establish haemolysis (HI: mean±SD 846±795 mg/L, range 150-3000 mg/L; Visual: 850±436 mg/L, 500-3000 mg/L). Sixteen studies reported the analyte of interest, with only three studies reporting a haemoglobin level at which the specimen would be rejected. Conclusion: Despite haemolysis being a frequent and costly problem with a negative impact on patient care, there is poor consistency in haemolysis detection and reporting between studies. Improved consistency would facilitate the generation of benchmark data used to create quality practices to monitor and reduce this leading cause of pre-analytical laboratory error.

Journal Title

Clinical Biochemist Reviews

Conference Title
Book Title
Edition
Volume

37

Issue

4

Thesis Type
Degree Program
School
DOI
Patent number
Funder(s)
Grant identifier(s)
Rights Statement
Rights Statement
Item Access Status
Note
Access the data
Related item(s)
Subject

Chemical sciences

Biomedical and clinical sciences

Persistent link to this record
Citation

McCaughey, EJ; Vecellio, E; Lake, R; Li, L; Burnett, L; Chesher, D; Braye, S; Mackay, M; Gay, S; Badrick, TC; Westbrook, JI; Georgiou, A, Current methods of haemolysis detection and reporting as a source of risk to patient safety: A narrative review, Clinical Biochemist Reviews, 2016, 37 (4), pp. 143-151

Collections